Effect of Reduced Dialysate Flow on Dialysis Adequacy: A Pilot Study
Authors' conclusion
Three months of Qd at 400 mL/min appears to provide similar small molecule and MM removal, but with an increase in pre-dialysis urea, creatinine, beta2-microglobulin, and myoglobin levels. Although this strategy could help preserve water, its potential impact on long-term clinical outcomes deserves further evaluation.
Study context
- Population
- Patients on different maintenance dialysis modalities with Qd set at 500 mL/min
- Participants
- 74 patients
- Exposure
- Qd 400 mL/min for 3 months vs Qd 500 mL/min
- Qd400n = 74
- Qd500n = 74reference
- Outcome
- Dialysis adequacy, including small solute removal and middle molecule RR
- Follow-up
- After 3 months
Methodological detailspilot study, before-after comparison
- Pilot study
- Before-after comparison
Main finding
As reported in the abstract
Qd400
1.41
± 0.30
Qd500
1.43
± 0.33
P = 0.58
Key notes
- Similar equilibrated Kt/V, urea RR, creatinine RR and phosphate RR
- Similar
Observational data: associations, not effects.
Further findings
After 3 months
Beta2-microglobulin RR · significantly higher with Qd400
P = 0.009
Kappa free light chain RR · lower with Qd400
P = 0.03
Pre-dialysis urea · after 3 months · higher with Qd400
P = 0.002
Pre-dialysis creatinine · after 3 months · higher with Qd400
P = 0.029
Pre-dialysis beta2-microglobulin · after 3 months · higher with Qd400
P = 0.0001
Pre-dialysis myoglobin · after 3 months · higher with Qd400
P = 0.033
Myoglobin and lambda free light chain (FLC) RR · after 3 months
- Myoglobin and lambda FLC RR were similar
Pre-dialysis albumin, potassium, bicarbonate, phosphate, calcium · after 3 months
- Similar between Qd400 and Qd500
Original publication