Effects of Low Dialysate Temperature on Intradialytic Hypotension and Dialysis Adequacy in Chronic Hemodialysis: A Systematic Review and Meta‐Analysis

Semin DialPublished Systematic review and meta-analysis of randomised crossover trials

Pooled result · Incidence of IDHResult — go to the resultOdds ratio 0.35 95% CI 0.28–0.46

Authors' conclusion

Maintaining low dialysate temperatures between 34.5°C and 36.0°C is recommended to reduce the incidence of IDH and improve dialysis adequacy in chronic hemodialysis patients. The specific low dialysate temperature should be individualized to minimize IDH risk, enhance patient comfort, and optimize treatment outcomes.

Study context

Population
Patients on chronic HD
Comparison
Low dialysate temperature vs comparator not named in the abstract
Outcome
Incidence of intradialytic hypotension (IDH)
Methodological detailssearched PubMed, Embase, CINAHL and Cochrane Library up to April 10, 2025, Cochrane Risk of Bias 2 tool, subgroup analysis by dialysate temperature
  • Searched PubMed, Embase, CINAHL and Cochrane Library up to April 10, 2025
  • Cochrane Risk of Bias 2 tool
  • Subgroup analysis by dialysate temperature

Pooled result

Incidence of IDH

Odds ratio

0.35

95% CI 0.28–0.46

P < 0.001

Low dialysate temperaturevs comparator not named in the abstract
OR 0.35 (95% CI 0.28–0.46); P < 0.001

As reported in the abstract

Further pooled results

Mean arterial pressure

SMD (95% CI)P value
Low dialysate temperature0.67 (0.38–0.96)P < 0.001

Mean systolic BP

SMD (95% CI)P value
Low dialysate temperature0.54 (0.30–0.79)P < 0.001

Urea clearance dialysis adequacy

SMD (95% CI)P value
Low dialysate temperatureImproved0.25 (0.03–0.47)P = 0.029

URR

SMD (95% CI)P value
Low dialysate temperatureImproved0.24 (0.02–0.47)P = 0.035

Intradialytic mean body temperature

SMD (95% CI)P value
Low dialysate temperature−0.68 (−0.99 to −0.37)P < 0.001

Subgroups by dialysate temperature

Dialysate temperatures between 34.5°C and 35.0°C were more effective in improving these outcomes than 35.1°C to 36.0°C

Original publication

Effects of Low Dialysate Temperature on Intradialytic Hypotension and Dialysis Adequacy in Chronic Hemodialysis: A Systematic Review and Meta‐Analysis. Semin Dial. Published 19 October 2025. doi:10.1111/sdi.70010

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.