Effects of Low Dialysate Temperature on Intradialytic Hypotension and Dialysis Adequacy in Chronic Hemodialysis: A Systematic Review and Meta‐Analysis
Pooled result · Incidence of IDHResult — go to the resultOdds ratio 0.35 95% CI 0.28–0.46Authors' conclusion
Maintaining low dialysate temperatures between 34.5°C and 36.0°C is recommended to reduce the incidence of IDH and improve dialysis adequacy in chronic hemodialysis patients. The specific low dialysate temperature should be individualized to minimize IDH risk, enhance patient comfort, and optimize treatment outcomes.
Study context
- Population
- Patients on chronic HD
- Comparison
- Low dialysate temperature vs comparator not named in the abstract
- Outcome
- Incidence of intradialytic hypotension (IDH)
Methodological detailssearched PubMed, Embase, CINAHL and Cochrane Library up to April 10, 2025, Cochrane Risk of Bias 2 tool, subgroup analysis by dialysate temperature
- Searched PubMed, Embase, CINAHL and Cochrane Library up to April 10, 2025
- Cochrane Risk of Bias 2 tool
- Subgroup analysis by dialysate temperature
Pooled result
Incidence of IDH
Odds ratio
0.35
95% CI 0.28–0.46
P < 0.001
Low dialysate temperaturevs comparator not named in the abstract
OR 0.35 (95% CI 0.28–0.46); P < 0.001
As reported in the abstract
Key notes
- Significantly decreased
Further pooled results
Mean arterial pressure
| SMD (95% CI) | P value | ||
|---|---|---|---|
| Low dialysate temperature | 0.67 (0.38–0.96) | P < 0.001 | |
| −0.500.51Difference (linear scale) |
Mean systolic BP
| SMD (95% CI) | P value | ||
|---|---|---|---|
| Low dialysate temperature | 0.54 (0.30–0.79) | P < 0.001 | |
| −0.500.51Difference (linear scale) |
Urea clearance dialysis adequacy
| SMD (95% CI) | P value | ||
|---|---|---|---|
| Low dialysate temperatureImproved | 0.25 (0.03–0.47) | P = 0.029 | |
| −0.200.20.40.6Difference (linear scale) |
URR
| SMD (95% CI) | P value | ||
|---|---|---|---|
| Low dialysate temperatureImproved | 0.24 (0.02–0.47) | P = 0.035 | |
| −0.200.20.40.6Difference (linear scale) |
Intradialytic mean body temperature
| SMD (95% CI) | P value | ||
|---|---|---|---|
| Low dialysate temperature | −0.68 (−0.99 to −0.37) | P < 0.001 | |
| −1−0.500.5Difference (linear scale) |
Subgroups by dialysate temperature
- Dialysate temperatures between 34.5°C and 35.0°C were more effective in improving these outcomes than 35.1°C to 36.0°C
Original publication
Effects of Low Dialysate Temperature on Intradialytic Hypotension and Dialysis Adequacy in Chronic Hemodialysis: A Systematic Review and Meta‐Analysis. Semin Dial. Published 19 October 2025. doi:10. 1111/ sdi. 70010
Composed by AI from the published abstract and checked against it. How Briefs are made →