Hemodialysis

How low can we go with the dialysate flow? A retrospective study on the safety and adequacy of a water-saving dialysis prescription

Clin Kidney JPublished Retrospective study

Authors' conclusion

Reduction in dialysate flow rate to 300 mL/min seems safe and does not cause any short-term negative effects in this small study. Thus, we might be able to achieve a similar therapeutic effect while saving water consumption. Larger, long-term studies incorporating patient-reported outcome measures are needed to confirm the efficacy of this approach.

Study context

Population
HD patients of a satellite dialysis center that temporarily reduced dialysate flow
Participants
24 patients
Exposure
Qd 300 mL/min for one month vs Qd 500 mL/min in the 3 months before and the 3 months after
Outcome
Dialysis adequacy (URR, Kt/V)
Methodological detailssingle satellite dialysis center, before-during-after comparison
  • Single satellite dialysis center
  • Before-during-after comparison

Main finding

As reported in the abstract

Dialysis adequacy (URR and Kt/V)
No significant changes in URR caused by lower Qd (ANOVA)
P = .50
HD adequacy expressed by Kt/V did not differ at any Qd (ANOVA)
P = .09

Observational data: associations, not effects.

Safety

Mean, mmol/L

OutcomeQd 500 mL/min (before)Qd 300 mL/minQd 500 mL/min (after)P value
Mean predialysis potassiumQd 300 mL/min vs Qd 500 mL/min (before) · small but statistically significant increase with lower Qd5.18 (95% CI 4.96–5.44)5.46 (95% CI 5.23–5.69)5.23 (95% CI 4.99–5.47)P = 0.039

Original publication

How low can we go with the dialysate flow? A retrospective study on the safety and adequacy of a water-saving dialysis prescription. Clin Kidney J. Published 8 August 2024. doi:10.1093/ckj/sfae238

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.