How low can we go with the dialysate flow? A retrospective study on the safety and adequacy of a water-saving dialysis prescription
Authors' conclusion
Reduction in dialysate flow rate to 300 mL/min seems safe and does not cause any short-term negative effects in this small study. Thus, we might be able to achieve a similar therapeutic effect while saving water consumption. Larger, long-term studies incorporating patient-reported outcome measures are needed to confirm the efficacy of this approach.
Study context
- Population
- HD patients of a satellite dialysis center that temporarily reduced dialysate flow
- Participants
- 24 patients
- Exposure
- Qd 300 mL/min for one month vs Qd 500 mL/min in the 3 months before and the 3 months after
- Outcome
- Dialysis adequacy (URR, Kt/V)
Methodological detailssingle satellite dialysis center, before-during-after comparison
- Single satellite dialysis center
- Before-during-after comparison
Main finding
As reported in the abstract
Dialysis adequacy (URR and Kt/V)
- No significant changes in URR caused by lower Qd (ANOVA)
- P = .50
- HD adequacy expressed by Kt/V did not differ at any Qd (ANOVA)
- P = .09
Key notes
- 24 analysed
Observational data: associations, not effects.
Safety
Mean, mmol/L
| Outcome | Qd 500 mL/min (before) | Qd 300 mL/min | Qd 500 mL/min (after) | P value |
|---|---|---|---|---|
| Mean predialysis potassiumQd 300 mL/min vs Qd 500 mL/min (before) · small but statistically significant increase with lower Qd | 5.18 (95% CI 4.96–5.44) | 5.46 (95% CI 5.23–5.69) | 5.23 (95% CI 4.99–5.47) | P = 0.039 |
Original publication
How low can we go with the dialysate flow? A retrospective study on the safety and adequacy of a water-saving dialysis prescription. Clin Kidney J. Published 8 August 2024. doi:10. 1093/ ckj/ sfae238