The weighing process in patients on hemodialysis: an opportunity to improve volume management
Authors' conclusion
A standardized template for clothing mass may be useful to derive representative predialysis BM, leading to more precise ultrafiltration calculation. Exact BM determination might improve volume management in hemodialysis.
Study context
- Population
- Patients on HD; dressed and undressed predialysis body mass measured
- Participants
- 48 patients
- Exposure
- Template-based clothing mass estimation vs conventional practice
- No estimationn = 36
- Self-estimatedn = 12
- Outcome
- Difference of predialysis BM from undressed BM
Methodological detailsBland-Altman plots, Wilcoxon signed rank tests
- Bland-Altman plots
- Wilcoxon signed rank tests
Main finding
As reported in the abstract
Average difference as share of average subsequent ultrafiltration volume, patient-reported body mass (BM)
39.4%
Average difference as share of average subsequent ultrafiltration volume, template-based BM
8.6%
Key notes
- Patients underestimated clothing mass
- No estimation: 36 patients (75%) used dressed BM as predialysis BM; Self-estimated: 12 patients (25%) deducted a self-estimated clothing mass
Observational data: associations, not effects.
Further findings
Difference from undressed BM, template-based clothing mass deduction
Average difference as share of average subsequent ultrafiltration volume
- Patient-reported BM
- 39.4%
- Template-based BM
- 8.6%
- Potential overestimation of actual ultrafiltration volume could be reduced