Hemodialysis

The weighing process in patients on hemodialysis: an opportunity to improve volume management

Clin Kidney JPublished Cross-sectional study

Authors' conclusion

A standardized template for clothing mass may be useful to derive representative predialysis BM, leading to more precise ultrafiltration calculation. Exact BM determination might improve volume management in hemodialysis.

Study context

Population
Patients on HD; dressed and undressed predialysis body mass measured
Participants
48 patients
Exposure
Template-based clothing mass estimation vs conventional practice
  • No estimationn = 36
  • Self-estimatedn = 12
Outcome
Difference of predialysis BM from undressed BM
Methodological detailsBland-Altman plots, Wilcoxon signed rank tests
  • Bland-Altman plots
  • Wilcoxon signed rank tests

Main finding

As reported in the abstract

Difference of predialysis BM from undressed BM

Average difference as share of average subsequent ultrafiltration volume, patient-reported body mass (BM)

39.4%

Average difference as share of average subsequent ultrafiltration volume, template-based BM

8.6%

Observational data: associations, not effects.

Further findings

Difference from undressed BM, template-based clothing mass deduction

Average difference as share of average subsequent ultrafiltration volume

Patient-reported BM
39.4%
Template-based BM
8.6%
  • Potential overestimation of actual ultrafiltration volume could be reduced

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

The weighing process in patients on hemodialysis: an opportunity to improve volume management. Clin Kidney J. Published 3 September 2024. doi:10.1093/ckj/sfae275

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.