Comparison of modeled versus reported phosphate removal and modeled versus postdialysis serum phosphate levels in conventional hemodialysis
Authors' conclusion
For conventional 4-h dialysis treatments, phosphate removal and postdialysis serum phosphate values predicted by a 2-pool kinetic model are similar to reported measured values.
Study context
- Population
- Patients on conventional HD, sessions close to 4 h (range 3 to 6 h)26 studies · 35 patient groups
- Comparison
- Modeled vs reported measured phosphate removal and postdialysis serum phosphate
- Outcome
- Phosphate removal per treatment, predicted vs measured
Methodological details2-pool kinetic model, group mean data from published studies
- 2-pool kinetic model
- Group mean data from published studies
Main finding
As reported in the abstract
Phosphate removal
Predicted
931
Mean · ± 170 · mg/treatment
Measured
900
± 287 · mg
P < 0.001
- Ratio of predicted/measured removal averaged
- 1.15 ± 0.427
Key notes
- Somewhat higher predicted
Further findings
| Outcome | Predicted | Measured | P value |
|---|---|---|---|
| Phosphate removal, excluding 5/35 groups (3/26 studies) with predicted/measured >1.50 | 966 | mean 990 mg | |
| Postdialysis serum phosphateNot significantly different | 2.60 ± 0.24 mg/dl | 2.64 ± 0.54 | P = NS |
- Phosphate removal, excluding 5/35 groups (3/26 studies) with predicted/measured >1.50 — Ratio of predicted/measured removal averaging
- 0.993
- Postdialysis serum phosphate: reported in 25/35 groups
Original publication
Comparison of modeled versus reported phosphate removal and modeled versus postdialysis serum phosphate levels in conventional hemodialysis. Semin Dial. Published 13 July 2022. doi:10. 1111/ sdi. 13112
Composed by AI from the published abstract and checked against it. How Briefs are made →