Residual Red Blood Cell Volume in Extracorporeal Blood Circuit after Hemodialysis: A Single-Center Study
Authors' conclusion
After HD, the remaining RBC volume in the extracorporeal blood circuit varies from 1.6 to 6.5 mL. When the RBC volume was converted to whole blood volume for each case, the blood loss ranged from 1.0 to 19.0 mL. Dialyzer surface area was the only significant determinant of residual RBC volume.
Study context
- Population
- ESRD patients undergoing hemodialysis (HD)
- Participants
- 70 patients
- Outcome
- Blood loss during HD: residual RBC volume in the extracorporeal blood circuit after HD
Methodological detailssingle-center, univariate and multivariate regression, Circuits rinsed after dialysis with 1,000 mL of 0.05% NH3 solution in distilled water; hemoglobin measured
- Single-center
- Univariate and multivariate regression
- Circuits rinsed after dialysis with 1,000 mL of 0.05% NH3 solution in distilled water; hemoglobin measured
Main finding
As reported in the abstract
Residual RBC volume in extracorporeal blood circuit after HD
- Residual red blood cell (RBC) volume, mean ± SD
- 1.6 ± 0.9 mL
- Residual RBC volume, mode
- 1.0
- Residual RBC volume, range
- 0.3-6.5 mL
- Whole blood volume per patient, mean ± SD
- 5.3 ± 3.0 mL
- Whole blood volume per patient, median
- 4.1 mL
- Whole blood volume per patient, mode
- 4.0 mL
- Whole blood volume per patient, range
- 1.0-19.0 mL
Further findings
- Multivariate analysis: dialyzer surface area the only significant determinant of residual RBC volume
Original publication
Residual Red Blood Cell Volume in Extracorporeal Blood Circuit after Hemodialysis: A Single-Center Study. Blood Purif. Published 15 October 2024. doi:10. 1159/ 000542004
Composed by AI from the published abstract and checked against it. How Briefs are made →