Hemodialysis

Residual Red Blood Cell Volume in Extracorporeal Blood Circuit after Hemodialysis: A Single-Center Study

Blood PurifPublished Cross-sectional study

Authors' conclusion

After HD, the remaining RBC volume in the extracorporeal blood circuit varies from 1.6 to 6.5 mL. When the RBC volume was converted to whole blood volume for each case, the blood loss ranged from 1.0 to 19.0 mL. Dialyzer surface area was the only significant determinant of residual RBC volume.

Study context

Population
ESRD patients undergoing hemodialysis (HD)
Participants
70 patients
Outcome
Blood loss during HD: residual RBC volume in the extracorporeal blood circuit after HD
Methodological detailssingle-center, univariate and multivariate regression, Circuits rinsed after dialysis with 1,000 mL of 0.05% NH3 solution in distilled water; hemoglobin measured
  • Single-center
  • Univariate and multivariate regression
  • Circuits rinsed after dialysis with 1,000 mL of 0.05% NH3 solution in distilled water; hemoglobin measured

Main finding

As reported in the abstract

Residual RBC volume in extracorporeal blood circuit after HD
Residual red blood cell (RBC) volume, mean ± SD
1.6 ± 0.9 mL
Residual RBC volume, mode
1.0
Residual RBC volume, range
0.3-6.5 mL
Whole blood volume per patient, mean ± SD
5.3 ± 3.0 mL
Whole blood volume per patient, median
4.1 mL
Whole blood volume per patient, mode
4.0 mL
Whole blood volume per patient, range
1.0-19.0 mL

Further findings

Multivariate analysis: dialyzer surface area the only significant determinant of residual RBC volume

Original publication

Residual Red Blood Cell Volume in Extracorporeal Blood Circuit after Hemodialysis: A Single-Center Study. Blood Purif. Published 15 October 2024. doi:10.1159/000542004

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.