Exploring clinical evaluation indicators for predicting coagulation in the extracorporeal circulation circuit in hemodialysis patients receiving individualized regional citrate anticoagulation—A single‐center, retrospective clinical study
Authors' conclusion
Individualized RCA can meet the needs of most HD treatments. Abnormal coagulation status in HD patients may increase the incidence of coagulation in the ECC circuit during individualized RCA for HD, and the D-dimer level can predict the occurrence of coagulation in the ECC circuit during this treatment.
Study context
- Population
- Hemodialysis (HD) patients receiving individualized regional citrate anticoagulation (RCA)
- Outcome
- Clinical coagulation status indicators predicting coagulation in the extracorporeal circulation (ECC) circuit
Methodological detailssingle-center
- Single-center
Main finding
As reported in the abstract
Prediction of coagulation in the ECC circuit
D-dimer level: independent risk factor that can predict coagulation in the extracorporeal circulation (ECC) circuit; cutoff value (mg/L)
2.03
D-dimer sensitivity
59%
D-dimer specificity
78%
Key notes
- Combined diseases or conditions affecting coagulation status in vivo may increase the incidence of coagulation in the ECC circuit
Further findings
- Patients with actual citrate infusion rate within ±10% of the theoretical rate
- nearly 80%
- Individualized RCA had a good anticoagulation effect
Original publication
Exploring clinical evaluation indicators for predicting coagulation in the extracorporeal circulation circuit in hemodialysis patients receiving individualized regional citrate anticoagulation—A single‐center, retrospective clinical study. Semin Dial. Published 5 October 2023. doi:10. 1111/ sdi. 13183