Hemodialysis

Prediction of intradialytic hypotension by machine learning: A systematic review

J NephrolPublished Systematic review

Authors' conclusion

Researchers have made a concerted effort to develop ML tools to predict intradialytic hypotension. Despite their significant efforts, the lack of thorough external and clinical validation, and heterogeneity among the models and settings have resulted in a substantial challenge to offering ML tools as a global intradialytic hypotension prevention and management solution. Future studies should focus on external and clinical validation of these models to enhance the chances of clinically relevant changes in clinical practices.

Study context

Population
Adult patients on HD; Machine learning (ML) models to predict intradialytic hypotension
Participants
14,500 patients16 studies
Outcome
ML models predicting intradialytic hypotension
Methodological detailspre-established protocol, six databases searched from inception to July 20, 2023, two independent investigators, risk of bias assessed with PROBAST
  • Pre-established protocol
  • Six databases searched from inception to July 20, 2023
  • Two independent investigators
  • Risk of bias assessed with PROBAST

Main finding

As reported in the abstract

ML models predicting intradialytic hypotension

Studies with high risk of bias

14

87.5%

Intradialytic hypotension prevalence in the populations investigated

between 1.2 and 51%

Neural networking models, the most frequent ML tools, in 13 studies: AUROC ranges

0.684-0.978

Studies performing both internal and external validation

1

Original publication

Prediction of intradialytic hypotension by machine learning: A systematic review. J Nephrol. Published 3 May 2025. doi:10.1007/s40620-025-02288-4

Composed by AI from the published abstract and checked against it. How Briefs are made →