Variations in Serum Albumin Levels Over Time in Patients Treated With Conventional Hemodialysis or Expanded Hemodialysis: A Cohort Study
Authors' conclusion
Variations in serum albumin levels over time were associated with protein-energy wasting, inflammation, high age, vascular access, and hospitalizations, but not with the type of dialyzer.
Study context
- Population
- Prevalent adult hemodialysis (HD) patients at Renal Care Services Colombia, enrolled September–November 2017
- Participants
- 1,092 patients
- Exposure
- HDx therapy with Theranova dialyzer vs conventional high-flux HD
- HDxn = 559
- HF-HDn = 533reference
- Outcome
- Serum albumin over time
- Follow-up
- Up to 48 months
Methodological detailsrepeated-measures analysis of variance (ANOVA), linear panel regression analysis
- Repeated-measures ANOVA
- Linear panel regression analysis
Main finding
As reported in the abstract
Mean serum albumin over time
- Mean albumin concentration remained above 3.8 g/dL and did not differ over time between HDx and HF-HD
- HDx vs HF-HD: P = 0.789
Observational data: associations, not effects.
Further findings
Association of time-varying serum albumin with Theranova dialyzer use (linear panel regression)
- No association between serum albumin levels varying over time and use of the Theranova dialyzer
- P = 0.208
Serum albumin and inflammatory/nutritional markers
- Serum albumin linked to C-reactive protein, platelet-to-lymphocyte ratio and protein-energy wasting