Hemodialysis

Real-time prediction of intradialytic hypotension using machine learning and cloud computing infrastructure

Nephrol Dial TransplantPublished Prognostic model development study

Authors' conclusion

Real-time prediction of IDH during an ongoing hemodialysis session is feasible and has a clinically actionable predictive performance. If and to what degree this predictive information facilitates the timely deployment of preventive interventions and translates into lower IDH rates and improved patient outcomes warrants prospective studies.

Study context

Population
In-center maintenance HD patients42,656 HD sessions
Participants
693 patients
Outcome
Predictive performance (AUROC) for IDH (SBP <90 mmHg) 15-75 min in advance
Follow-up
15-75 min in advance
Methodological detailsmachine learning, real-time cloud computing, random 80%/20% training/testing split of sessions, 355 693 intradialytic systolic blood pressure (SBP) measurements
  • Machine learning
  • Real-time cloud computing
  • Random 80%/20% training/testing split of sessions
  • 355 693 intradialytic SBP measurements

Performance

As reported in the abstract

Prediction of IDH 15-75 min in advance

AUROC

0.89

Further findings

Intradialytic hypotension (IDH) incidence

IDH occurred in HD treatments
16.2%

Top IDH predictors

Most recent intradialytic SBP and IDH rate, and mean nadir SBP of the previous 10 dialysis sessions

Original publication

Real-time prediction of intradialytic hypotension using machine learning and cloud computing infrastructure. Nephrol Dial Transplant. Published 13 April 2023. doi:10.1093/ndt/gfad070

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.