Hemodialysis

Incidence of hospital admissions in bioimpedance‐guided fluid management among maintenance hemodialysis patients—Results of a randomized controlled trial

Hemodial IntPublished Randomised controlled trial

Authors' conclusion

The inclusion of bioimpedance data to guide the estimation of target weight in hemodialysis patients had no detectable impact on survival or BP control, but significantly reduced the incidence rate of hospital admissions. The study was

Study context

Population
Adults on maintenance HD
Participants
110 adults
Comparison
Target weight estimation by monthly clinical evaluation plus bioimpedance twice a year vs clinical evaluation alone
  • Bioimpedancen = 58
  • Usual caren = 52reference
Primary endpoint
Survival
Follow-up
2 years
Methodological detailsopen-label, parallel-group
  • Open-label
  • Parallel-group

Primary result

As reported in the abstract

  • Bioimpedance vs Usual care: P = 0.68
  • Trial underpowered for this outcome

Secondary outcomes

Per person-year

OutcomeBioimpedanceUsual careTime-adjusted IRR (95% CI)P value
Hospital admissions2.13.11.48 (1.20–1.82)P = 0.0001
Hospital admissions — Attributable fraction of risk among exposed individuals
0.32 (95% CI: 0.17-0.45)

Blood pressure (BP) and antihypertensive drugs

No difference between groups in change in systolic or diastolic BP or in number of antihypertensive drugs

Original publication

Incidence of hospital admissions in bioimpedance‐guided fluid management among maintenance hemodialysis patients—Results of a randomized controlled trial. Hemodial Int. Published 17 April 2023. doi:10.1111/hdi.13076

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.