Hemodynamic effects of low versus high dialysate bicarbonate concentration in hemodialysis patients
An erratum to this article was published (Hemodial Int, Apr 2025 ↗)
Authors' conclusion
The use of high dialysate bicarbonate compared to low dialysate bicarbonate was associated with hypocalcemia, alkalosis, and a more pronounced hypokalemia. During hemodialysis with UF, a better preservation of blood pressure, stroke volume, and cardiac output may be achieved with low dialysate bicarbonate compared to high dialysate bicarbonate.
Study context
- Population
- HD patients
- Participants
- 15 patients
- Comparison
- Low vs high dialysate bicarbonate during a 4-h HD session
- Low dialysate bicarbonaten = 15
- High dialysate bicarbonaten = 15reference
- Primary endpoint
- BP, intradialytic hemodynamic parameters, orthostatic BP and electrolytes
Methodological detailssingle-blind, crossover, 1 week between interventions
- Single-blind
- Crossover
- 1 week between interventions
Primary result
As reported in the abstract
Mean between treatment difference
8 mmHg
95% CI −4 to 20
end of HD; Systolic blood pressure (SBP) tended to decrease more during high dialysate bicarbonate
Mean between treatment difference
7 mmHg
95% CI 0–15
post-HD; SBP tended to decrease more during high dialysate bicarbonate
Key notes
- Similar ultrafiltration (UF) volume (2.6 L)
Further findings
| Outcome | Mean between treatment difference (mmHg/(L/min)) (CI) | |
|---|---|---|
| Total peripheral resistance | −2.9 (−5.3 to −0.5) | |
| −10−505Difference, mmHg/(L/min) (linear scale) |
| Outcome | Estimate |
|---|---|
| Stroke volume | mean between treatment difference 12 mL (CI 1–23) |
| Cardiac outputTended to decrease more with high dialysate bicarbonate | mean between treatment difference 0.7 L/min (CI 0.0–1.4) |
- Stroke volume: decreased significantly more during high dialysate bicarbonate
- Total peripheral resistance: increased significantly more during high dialysate bicarbonate
Orthostatic BP · after dialysis
- Orthostatic BP response after dialysis did not differ significantly
Safety
Acid-base and electrolytes
- High dialysate bicarbonate caused alkalosis, hypocalcemia and lower plasma potassium
- Patients remained normocalcemic with normal pH during low dialysate bicarbonate
Original publication