Hemodialysis

Application of therapeutic ultrasonic waves across the dialyzer membrane: A pilot study on the impact on dialyzer clearance and safety

Hemodial IntPublished Crossover pilot study

Authors' conclusion

Intradialytic clogging of dialyzer membranes is a significant problem that can cause dialysis inadequacy. Our study tackles this issue by introducing therapeutic ultrasonic waves to improve dialyzer clearance during hemodialysis sessions in patients.

Study context

Population
Stable maintenance HD patients12 males · 3 females
Participants
15 patients
Comparison
HD session with therapeutic ultrasonic waves vs HD session without ultrasonic waves
Outcome
Decline in dialyzer clearance (Online Clearance Monitoring)
Methodological detailseach patient own control
  • Each patient own control

Main finding

As reported in the abstract

Mean percentage decline in dialyzer clearance

Ultrasonic session

4.41%

mean · SD 5.3

Control session

12.69%

mean · SD 6.35

P < 0.001

Safety

Mean differences of blood component parameters comparable between Ultrasonic and Control sessions
  • Microscopic membrane analysis corroborated safety

Original publication

Application of therapeutic ultrasonic waves across the dialyzer membrane: A pilot study on the impact on dialyzer clearance and safety. Hemodial Int. Published 24 May 2024. doi:10.1111/hdi.13161

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.