Effects of dialysate potassium concentration of 3.0 mmol/l with sodium zirconium cyclosilicate on dialysis-free days versus dialysate potassium concentration of 2.0 mmol/l alone on rates of cardiac arrhythmias in hemodialysis patients with hyperkalemia
An erratum to this article was published (Kidney Int, Jun 2025 ↗)
Primary result · AF episodes (unadjusted rate)Result — go to the resultModeled rate ratio 0.52 95% CI 0.41–0.65Authors' conclusion
Thus, in patients with hyperkalemia on maintenance hemodialysis, a combination of hemodialysate potassium 3.0 mmol/l and SZC on non-hemodialysis days reduced the rates of AF, other clinically significant arrhythmias, and post-dialysis hypokalemia compared with hemodialysate potassium 2.0/noSZC.
Study context
- Population
- Adults receiving HD for three months or more with hyperkalemia (pre-dialysis sK+ 5.1–6.5 mmol/l)25.5 person-years follow-up
- Participants
- 88 adults
- Comparison
- Dialysate potassium 3.0 mmol/l with sodium zirconium cyclosilicate (SZC) on non-dialysis days vs dialysate potassium 2.0 mmol/l without SZC, 8 weeks each, then crossover
- Primary endpoint
- Rate of adjudicated AF episodes of at least 2 minutes duration
Methodological detailscrossover, implanted cardiac monitors, adjudicated atrial fibrillation (AF) episodes
- Crossover
- Implanted cardiac monitors
- Adjudicated AF episodes
Primary result
AF episodes (unadjusted rate)
3.0 potassium/SZCvs 2.0 potassium/noSZC
modeled rate ratio 0.52 (95% CI 0.41–0.65)
As reported in the abstract
Key notes
- 296 AF episodes detected in nine patients
Secondary outcomes
Clinically significant arrhythmias (bradycardia, ventricular tachycardia, and/or asystole) · printed as "0.47; 0.38; 0.58"
modeled rate ratio 0.47
| Outcome | Modeled OR (CI) | |
|---|---|---|
| sK+ measurements outside the optimal window (4.0-5.5 mmol/l)Fewer with 3.0 potassium/SZC | 0.27 (0.12–0.35) | |
| 0.10.31310Modeled OR (log scale) |
Safety
Events
| Outcome | 3.0 potassium/SZC | 2.0 potassium/noSZC |
|---|---|---|
| Hypokalemia | 33 | 58 |
- Hypokalemia: less frequent with 3.0 potassium/SZC
Original publication
Effects of dialysate potassium concentration of 3.0 mmol/l with sodium zirconium cyclosilicate on dialysis-free days versus dialysate potassium concentration of 2.0 mmol/l alone on rates of cardiac arrhythmias in hemodialysis patients with hyperkalemia. Kidney Int. Published 26 October 2024. doi:10. 1016/ j. kint. 2024. 10. 010
Composed by AI from the published abstract and checked against it. How Briefs are made →