Effect of Lowering Dialysate Flow Rate on Dialysis Dose and Laboratory Values
Authors' conclusion
In patients treated using the same dialysate filter and dialysis access, changing the dialysate flow rate from 800 to 600 mL/min does not result in clinically significant changes in either patients' measured serum electrolytes or dialysis dose.
Study context
- Population
- Adult (age ≥18 years) in-center HD patients dialysed at the centers 3 months before and after the change in dialysate flow rate (December 2022 to May 2023)
- Participants
- 68 participants
- Exposure
- Dialysate flow rate 600 vs 800 mL/min, same access and dialysis membrane
- Outcome
- Dialysis dose (Kt/Vurea)
Methodological detailssingle-center, before-after comparison
- Single-center
- Before-after comparison
Main finding
As reported in the abstract
Dialysis dose (Kt/Vurea)
All regression coefficients below 0.05 (a 0.05 change in dialysis dose for 600 vs 800 mL/min)
<0.05
Key notes
- No statistically significant change in dialysis dose with the change of dialysate flow rate
Observational data: associations, not effects.
Further findings
Dialysis dose by blood flow rate and dialysate sodium
- Significant associations between dialysis dose and both blood flow rate and dialysate sodium, but clinically negligible differences
Serum laboratory values (sodium, potassium, bicarbonate, BUN, creatinine)
- No statistically significant difference in serum electrolyte values
Original publication
Effect of Lowering Dialysate Flow Rate on Dialysis Dose and Laboratory Values. Blood Purif. Published 15 April 2025. doi:10. 1159/ 000545898
Composed by AI from the published abstract and checked against it. How Briefs are made →