Toward Green Dialysis: Efficacy and Sustainability with Reduced Dialysate Flow in Expanded Hemodialysis
Authors' conclusion
Using Qd 400 mL/min in HDx vs. 500 mL/min did not affect dialysis effectiveness in terms of molecule reduction rates and resulted in substantial water savings in Qd 400 mL/min group. </p>.
Study context
- Population
- Patients weighing ≤70 kg on expanded HD (HDx), COREXH study population
- Participants
- 23 patients
- Comparison
- Qd 400 mL/min vs Qd 500 mL/min in HDx using Theranova membrane
- Qd 400 mL/minn = 11
- Qd 500 mL/minn = 12reference
- Primary endpoint
- Reduction rate of medium-sized molecules
Methodological detailsobservational, analytical
- Observational
- Analytical
Primary result
As reported in the abstract
- No statistically significant differences between the Qd 400 mL/min and 500 mL/min groups
Further findings
Water consumption
L
- Lower with Qd 400 mL/min; average saving per patient per session
- 24
- Saving over 12 weeks
- 13,824
Original publication
Toward Green Dialysis: Efficacy and Sustainability with Reduced Dialysate Flow in Expanded Hemodialysis. Blood Purif. Published 30 October 2025. doi:10. 1159/ 000548892