Dynamics of Plasma Refill Rate and Intradialytic Hypotension During Hemodialysis: Retrospective Cohort Study With Causal Methodology
Authors' conclusion
We present a straightforward technique to quantify plasma refill that could easily integrate with devices that monitor hematocrit during HD. Our study highlights how examining patterns of plasma refill may enhance our understanding of circulatory changes during HD, an important step to understand how current technology might be used to improve hemodynamic instability.
Study context
- Population
- Patients receiving maintenance hemodialysis (HD) at 17 dialysis units, January 2017 to October 2019180,319 HD sessions
- Participants
- 2,554 patients
- Exposure
- Low or high vs moderate plasma refill rate during HD
- Outcome
- Intradialytic hypotension (IDH) by starting PRR and time-varying PRR
Methodological details17 dialysis units, Cox proportional hazard regression, marginal structural modeling, logistic regression
- 17 dialysis units
- Cox proportional hazard regression
- Marginal structural modeling
- Logistic regression
Main finding
As reported in the abstract
IDH by starting PRR
Each group vs moderate PRRHazard ratio (95% CI)
Low PRRlow starting PRR; higher hazard of IDH
1.26(1.18–1.35)
High PRRhigh starting PRR; protective
0.79(0.73–0.85)
Observational data: associations, not effects.
Further findings
Hypotension within the next 15 minutes, time-varying plasma refill rate (PRR) (marginal structural model)
| Outcome | OR (95% CI) | |
|---|---|---|
| Low PRRvs Moderate PRRConsistently low PRR · accounting for time-varying PRR and time-varying confounders | 1.09 (1.02–1.16) | |
| High PRRvs Moderate PRRConsistently high PRR · stronger association · accounting for time-varying PRR and time-varying confounders | 1.38 (1.30–1.45) | |
| 0.512Odds ratio (log scale) |
Factors associated with low PRR · first hour of HD
- Female sex and hypoalbuminemia associated with low PRR at multiple time points
- PRR had high within-patient and between-patient variability
Original publication
Dynamics of Plasma Refill Rate and Intradialytic Hypotension During Hemodialysis: Retrospective Cohort Study With Causal Methodology. Kidney360. Published 14 February 2023. doi:10. 34067/ kid. 0000000000000082
Composed by AI from the published abstract and checked against it. How Briefs are made →