Reducing intradialytic hypotension with intermittent pneumatic compression during haemodialysis: a randomized controlled trial
Authors' conclusion
Intradialytic IPC promotes haemodynamic indicators and reduces IDH occurrence in patients undergoing MHD. The compliance and safety of intradialytic IPC were satisfactory. Intradialytic IPC could be implemented in clinical settings to maintain haemodynamic stability during HD.
Study context
- Population
- Patients undergoing maintenance haemodialysis (HD)26 completed
- Participants
- 30 patients
- Comparison
- Intermittent pneumatic compression (IPC) during all dialysis sessions for 12 weeks vs usual care
- IPCn = 14
- Controln = 16reference
- Primary endpoint
- Intradialytic haemodynamic changes (BP and heart rate)
Primary result
As reported in the abstract
Changes in haemodynamic indicators (BP and heart rate) from pre-dialysis · all time points during dialysis
- IPC vs Control: P < 0.05
- Generalized estimating equation model
Further findings
- Incidence of intradialytic hypotension (IDH) · lower with IPC
- P < 0.01
- Adherence to IPC
- 94.2%
Original publication
Reducing intradialytic hypotension with intermittent pneumatic compression during haemodialysis: a randomized controlled trial. Clin Kidney J. Published 14 October 2025. doi:10. 1093/ ckj/ sfaf317
Composed by AI from the published abstract and checked against it. How Briefs are made →