Hemodialysis

Development and validation of AI-based triage support algorithms for prevention of intradialytic hypotension

J NephrolPublished Prognostic model development and validation study

Authors' conclusion

Recurrent symptomatic intradialytic hypotension could be reliably and accurately predicted using routinely collected data during dialysis treatment and standard clinical care. Clinical application of these prediction models would allow for personalized risk-based interventions for preventing and managing intradialytic hypotension.

Study context

Population
Dialysis sessions in the EuCliD® Database1,249,813 dialysis sessions
Outcome
Occurrence of symptomatic intradialytic hypotension in the next dialysis session and in the next month
Follow-up
Next dialysis session and next month
Methodological detailsXGBoost algorithm, routinely collected data (EuCliD® Database), derivation, training and validation split, SHAP feature importance
  • XGBoost algorithm
  • Routinely collected data (EuCliD® Database)
  • Derivation, training and validation split
  • SHAP feature importance

Performance

As reported in the abstract

Model performance for predicting intradialytic hypotension

Discrimination (AUC)

around 0.8

Further findings

Incidence rate of intradialytic hypotension

Incidence rate
10.07% (95% CI 10.02-10.13)

Feature importance

Most significant impact on risk estimates: BP dynamics and other metrics mirroring hemodynamic instability over time

Original publication

Development and validation of AI-based triage support algorithms for prevention of intradialytic hypotension. J Nephrol. Published 14 September 2023. doi:10.1007/s40620-023-01741-6

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.