Hemodialysis

The BestShape artificial intelligence system for real-time prediction of intradialytic hypotension—clinical outcomes after four-year follow-up

Clin Kidney JPublished Retrospective cohort study

Authors' conclusion

Preliminary clinical data show BestShape is associated with reductions in IDH, CPR, and falls in patients undergoing HD, and a reduction in healthcare costs and high medical personnel satisfaction.

Study context

Population
Patients on chronic hemodialysis (HD) at two institutions in Taiwan213,071 HD sessions
Participants
18,141 patients
Exposure
BestShape AI system for real-time intradialytic hypotension (IDH) prediction vs historical control
Outcome
IDH frequency
Methodological detailshistorical control, two institutions in Taiwan
  • Historical control
  • Two institutions in Taiwan

Main finding

As reported in the abstract

Mean monthly IDH rate
Mean monthly IDH rate, 2019
27%
Mean monthly IDH rate, 2023
21%
Significant reduction from 2019 to 2023
P < .001

Observational data: associations, not effects.

Secondary outcomes

OutcomeP value
Mortality during HDBefore BestShape vs After BestShape · 8% vs 9.3%; not significantly differentP = 0.260

Cardiopulmonary resuscitation (CPR) during dialysis

CPR per month, decreased from
eight
CPR per month, decreased to
three

Post-dialysis falls

Falls, decreased from
21
Falls, decreased to
seven

Estimated annual cost savings

Estimated annual cost savings with BestShape
USD 115 658

Medical personnel satisfaction

Mean satisfaction score
86

Original publication

The BestShape artificial intelligence system for real-time prediction of intradialytic hypotension—clinical outcomes after four-year follow-up. Clin Kidney J. Published 28 October 2025. doi:10.1093/ckj/sfaf323

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.