Hemodialysis

Continuous measurement of pulse arrival time for identification of blood pressure changes in patients undergoing hemodialysis—a feasibility study

Clin Kidney JPublished Feasibility study

Authors' conclusion

The study demonstrates that tracking BP changes using PAT as a non-invasive method in hemodialysis patients is feasible. However, the reliability of PAT measurements appears to vary among patients, indicating that this method may not be universally applicable. The observed inverse association between PAT and BP changes, especially during the start to middle phase of dialysis, highlights the potential of this technique to complement traditional monitoring methods. These exploratory findings open avenues for further research to validate the utility of PAT, particularly in predicting IDH episodes and assessing its behavior in scenarios of low BP or minimal variations.

Study context

Population
ESRD patients undergoing HD, Klinikum rechts der Isar, Technical University of Munichmean age 64.9 (SD 18.1) years
Participants
44 patients
Outcome
Changes in pulse arrival time (PAT) and BP during three predefined 1-hour periods of dialysis
Follow-up
Three predefined time periods of 1 hour during dialysis
Methodological detailssingle-centre, equivalence testing (TOST), correlation and classification analysis
  • Single-centre
  • Equivalence testing (TOST)
  • Correlation and classification analysis

Main finding

As reported in the abstract

Association of PAT changes with BP changes

Correlation of pulse arrival time (PAT) with SBP/DBP changes, r

−0.45

P < .001

Correlation of PAT with DBP changes, r

−0.25

P = .003

Equivalence of inverted PAT changes and SBP changes

P1 = .002 and P2 = .013

Equivalence of inverted PAT changes and DBP changes

P1 < .001 and P2 = .037

Further findings

Baseline measurements

Mean SBP, mmHg
137 (SD 30.1)
Mean diastolic blood pressure (BP), mmHg
68.4 (SD 18.4)
Mean PAT, ms
233 (SD 42.3)

Classification of patients as SBP decliners, risers or stable using relative PAT changes

F1-score
0.67
Sensitivity
62.7%
Specificity
70.9%
AUC (ROC analysis)
0.70
  • Moderate results

Original publication

Continuous measurement of pulse arrival time for identification of blood pressure changes in patients undergoing hemodialysis—a feasibility study. Clin Kidney J. Published 23 October 2025. doi:10.1093/ckj/sfaf255

Composed by AI from the published abstract and checked against it. How Briefs are made →