Kidney transplantation

Clinical performance of the iPREDICTLIVING tool for the prediction of the post‐transplant recipient and living donor outcomes in a European cohort

Clin TransplantPublished External validation study of a prediction tool

Authors' conclusion

These models have moderate discriminative and calibration performance in our population.

Study context

Population
Living donor kidney transplant (LDKT) donor–recipient pairs submitted to KT from 1998 to 2019, Northern Portuguese cohort352 LDKT pairs
Comparison
Censored graft failure (CGF) model vs Recipient death model vs Donor death model
Outcome
Predictive performance (discrimination and calibration) of the iPREDICTLIVING tool for graft loss, recipient death and donor death
Methodological detailsretrospective cohort
  • Retrospective cohort

Performance

As reported in the abstract

Predictive performance of the iPREDICTLIVING models
Test or modelHarrell's CTime-dependent AUCCalibration slopeHarrell's C at 10 yearsTime-dependent AUC at 10 yearsCalibration slope at 10 yearsHarrell's C (20 years)AUC (20 years)Calibration slope (20 years)
CGF model.665.566.998— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract
Recipient death model— not stated in the abstract— not stated in the abstract— not stated in the abstract.776.7731.003— not stated in the abstract— not stated in the abstract— not stated in the abstract
Donor death model— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract.712.694.955

Harrell's C

CGF model.665
Recipient death model— not stated in the abstract
Donor death model— not stated in the abstract

Time-dependent AUC

CGF model.566
Recipient death model— not stated in the abstract
Donor death model— not stated in the abstract

Calibration slope

CGF model.998
Recipient death model— not stated in the abstract
Donor death model— not stated in the abstract

Harrell's C at 10 years

CGF model— not stated in the abstract
Recipient death model.776
Donor death model— not stated in the abstract

Time-dependent AUC at 10 years

CGF model— not stated in the abstract
Recipient death model.773
Donor death model— not stated in the abstract

Calibration slope at 10 years

CGF model— not stated in the abstract
Recipient death model1.003
Donor death model— not stated in the abstract

Harrell's C (20 years)

CGF model— not stated in the abstract
Recipient death model— not stated in the abstract
Donor death model.712

AUC (20 years)

CGF model— not stated in the abstract
Recipient death model— not stated in the abstract
Donor death model.694

Calibration slope (20 years)

CGF model— not stated in the abstract
Recipient death model— not stated in the abstract
Donor death model.955

Original publication

Clinical performance of the iPREDICTLIVING tool for the prediction of the post‐transplant recipient and living donor outcomes in a European cohort. Clin Transplant. Published 14 March 2024. doi:10.1111/ctr.15283