Performance of Scores Predicting Adverse Outcomes in Procurement Kidney Biopsies From Deceased Donors With Organs of Lower-Than-Average Quality
Authors' conclusion
Our study shows an unmet need for practical prognostic scores useful at the time of a decision about discarding or accepting deceased donor kidneys of lower-than-average quality in the Eurotransplant consortium.
Study context
- Population
- Deceased donors with kidneys of lower-than-average quality and procurement biopsies, and their recipients223 biopsies · 223 recipient records
- Participants
- 221 donors
- Exposure
- 15 prognostic scores compared for prediction of DGF, graft function and death-censored graft loss
- Outcome
- Performance of scores on DGF, graft function or death-censored graft loss
Methodological detailsvalidation of 15 prognostic scores
- Validation of 15 prognostic scores
Main finding
As reported in the abstract
Score performance
| Group | AUC for DGF | AUC for transplant loss | AUCs for transplant loss |
|---|---|---|---|
| Chapal score | 0.709 | — not stated in the abstract | — not stated in the abstract |
| Irish score | 0.684 | — not stated in the abstract | — not stated in the abstract |
| Snoeijs score | — not stated in the abstract | 0.630 | — not stated in the abstract |
| Leuven scores | — not stated in the abstract | — not stated in the abstract | 0.637 and 0.620 |
AUC for DGF
Chapal score0.709
Irish score0.684
Snoeijs score— not stated in the abstract
Leuven scores— not stated in the abstract
AUC for transplant loss
Chapal score— not stated in the abstract
Irish score— not stated in the abstract
Snoeijs score0.630
Leuven scores— not stated in the abstract
AUCs for transplant loss
Chapal score— not stated in the abstract
Irish score— not stated in the abstract
Snoeijs score— not stated in the abstract
Leuven scores0.637 and 0.620
Key notes
- Best-performing score for graft function: Nyberg score
- Only score with acceptable performance: Chapal score; requires cold ischemia time, not known at allocation
More notes
- None of the other scores performed acceptably
Observational data: associations, not effects.
Further findings
- Scores fared better in discarded kidneys than in transplanted kidneys
Original publication