Comparing the prognostic performance of iBOX and biopsy-proven acute rejection for long-term kidney graft survival
Authors' conclusion
IBOX at 1-year posttransplant is superior to BPAR in the first year posttransplant in graft loss prognostic performance, providing valuable additional information and facilitating the demonstration of superiority of novel immunosuppressive regimens.
Study context
- Population
- Kidney transplant recipients4 data sets
- Participants
- 1,534 recipients
- Comparison
- iBOX vs biopsy-proven acute rejection (BPAR) for prognosis of death-censored graft survival
- Outcome
- Prognostic performance (discrimination, c-statistic) for death-censored graft survival
Methodological detailspooled cohort, 4 data sets, including 2 prospective RCTs, discrimination and calibration analyses
- Pooled cohort
- 4 data sets, including 2 prospective RCTs
- Discrimination and calibration analyses
Performance
As reported in the abstract
Discrimination for death-censored graft survival (c-statistic)
Mean c-statistic difference
0.25
95% CI 0.17–0.32
Full iBOX
Mean c-statistic difference
0.24
95% CI 0.16–0.32
Abbreviated iBOX
Full iBOX
0.81
mean · SE 0.03
Abbreviated iBOX
0.80
mean · SE 0.03
BPAR
0.57
mean · SE 0.03
Key notes
- Statistically significantly higher c-statistic values for iBOX
Further findings
Calibration: predicted vs observed graft loss events
- Observed graft loss events
- 64
- Predicted events, full iBOX
- 70
- Predicted events, abbreviated iBOX
- 76
- Predicted events, BPAR
- 173
- BPAR: predicted significantly different from observed
- P < 0.01
- Both iBOX models: predicted not significantly different from observed
Original publication
Comparing the prognostic performance of iBOX and biopsy-proven acute rejection for long-term kidney graft survival. Am J Transplant. Published 19 April 2024. doi:10. 1016/ j. ajt. 2024. 04. 004
Composed by AI from the published abstract and checked against it. How Briefs are made →