Electrolytes, acid–base & stones

Artificial Intelligence-Enabled Electrocardiography for Monitoring Serum Potassium Dynamics in Patients With Severe Hypokalemia

Am J Kidney DisPublished Retrospective cohort study

Authors' conclusion

AI-ECG enables real-time, within-patient monitoring of serum K+ dynamics during treatment for severe hypokalemia, with superior performance in the setting of acute hypokalemia due to K+ shift. As a noninvasive adjunct, AI-ECG may shorten the time to detect changes in K+ and reduce the need for lab-K+ measurements rather than relying exclusively on lab-K+. Confirmatory studies are warranted.

Study context

Population
Adults with severe hypokalemia (lab-K+ ≤ 2.5 mmol/L; matched ECG-K+ < 3.5 mmol/L) and ≥1 follow-up paired measurement within 24 hours of K+ supplementation
Participants
191 adults
Exposure
Electrocardiogram (ECG)-estimated K+ (AI-ECG) vs laboratory-measured K+, overall and by hypokalemia etiology (acute K+ shift vs chronic K+ deficit)
  • Acute K+ shiftn = 35
  • Chronic K+ deficitn = 156
Outcome
Agreement between paired ECG-K+ and lab-K+
Methodological detailsmulticenter, 3 teaching hospitals, Linear mixed-effects models with patient-level random intercepts; rmcorr and Bland-Altman plots; patient-level clustered bootstrapped ROC analysis
  • Multicenter
  • 3 teaching hospitals
  • Linear mixed-effects models with patient-level random intercepts; rmcorr and Bland-Altman plots; patient-level clustered bootstrapped ROC analysis

Main finding

As reported in the abstract

Agreement between ECG-K+ and lab-K+
ECG-K+ correlated strongly with lab-K+ (rmcorr)
0.847 (95% CI, 0.81-0.88), P < 0.001
Relationship modified by hypokalemia etiology, lower correlation with chronic K+ deficits
interaction P < 0.0001

Observational data: associations, not effects.

Further findings

K+ correction rate

  • K+ correction rate: ≈3-fold faster with acute K+ shift

Diagnostic accuracy of ECG-K+ for lab-K+ < 3.5 mmol/L

AUC
0.920 (95% CI, 0.863-0.961)
Higher with acute K+ shift

Timing of ECG-K+ vs lab-K+

ECG-K+ preceded lab-K+ results by a mean of
52.5 minutes

Safety

Rebound hyperkalemia detected by ECG-K+ before laboratory confirmation

Patients
2

Original publication

Artificial Intelligence-Enabled Electrocardiography for Monitoring Serum Potassium Dynamics in Patients With Severe Hypokalemia. Am J Kidney Dis. Published 13 August 2026. doi:10.1053/j.ajkd.2026.05.020

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.