Validation of a Clinical Scale for Early Detection of Infections at the Exit Site of Central Venous Catheters for Hemodialysis
Authors' conclusion
The validation shows that the scale has good predictive properties, detecting approximately 90% of ESI with very acceptable validity parameters.
Study context
- Population
- Adult patients with a tunneled central venous catheters for hemodialysis (CVC-HD) for at least 1 month after insertion515 cultures
- Participants
- 310 patients337 CVC-HDs
- Outcome
- Predictive accuracy of the scale for exit-site infection (exit-site infections (ESI)) vs pericatheter skin swab culture
Methodological detailsmulticenter, prospective cohort, ROC curves and logistic regression analysis, Exit site assessed by nurses with the scale at each HD session; swab culture collected if any item present
- Multicenter
- Prospective cohort
- ROC curves and logistic regression analysis
- Exit site assessed by nurses with the scale at each HD session; swab culture collected if any item present
Performance
As reported in the abstract
Predictive performance of the final 3-item scale for ESI (positive pericatheter skin swab culture as gold standard)
Final version of the scale: AUC
88.3%
95% CI 85.2%–91%P < 0.001
Final version of the scale: Youden index
0.7557
Final version of the scale: sensitivity
80.34%
95% CI 71.36%–87.71%
Final version of the scale: specificity
95.23%
95% CI 92.73%–97%
Key notes
- Final scale: pain at exit site during interdialytic period, hyperemia or erythema ≥2 cm from exit site, abscess or purulent exudate at exit site
- 515 cultures (117 infected, 398 healthy)
Original publication
Validation of a Clinical Scale for Early Detection of Infections at the Exit Site of Central Venous Catheters for Hemodialysis. Kidney Int Rep. Published 28 June 2024. doi:10. 1016/ j. ekir. 2024. 06. 034
Composed by AI from the published abstract and checked against it. How Briefs are made →