Hemodialysis

Validation of a Clinical Scale for Early Detection of Infections at the Exit Site of Central Venous Catheters for Hemodialysis

Kidney Int RepPublished Diagnostic accuracy study

Authors' conclusion

The validation shows that the scale has good predictive properties, detecting approximately 90% of ESI with very acceptable validity parameters.

Study context

Population
Adult patients with a tunneled central venous catheters for hemodialysis (CVC-HD) for at least 1 month after insertion515 cultures
Participants
310 patients337 CVC-HDs
Outcome
Predictive accuracy of the scale for exit-site infection (exit-site infections (ESI)) vs pericatheter skin swab culture
Methodological detailsmulticenter, prospective cohort, ROC curves and logistic regression analysis, Exit site assessed by nurses with the scale at each HD session; swab culture collected if any item present
  • Multicenter
  • Prospective cohort
  • ROC curves and logistic regression analysis
  • Exit site assessed by nurses with the scale at each HD session; swab culture collected if any item present

Performance

As reported in the abstract

Predictive performance of the final 3-item scale for ESI (positive pericatheter skin swab culture as gold standard)

Final version of the scale: AUC

88.3%

95% CI 85.2%–91%P < 0.001

Final version of the scale: Youden index

0.7557

Final version of the scale: sensitivity

80.34%

95% CI 71.36%–87.71%

Final version of the scale: specificity

95.23%

95% CI 92.73%–97%

Original publication

Validation of a Clinical Scale for Early Detection of Infections at the Exit Site of Central Venous Catheters for Hemodialysis. Kidney Int Rep. Published 28 June 2024. doi:10.1016/j.ekir.2024.06.034

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.