Hemodialysis

A New Procedure for Guidewire Exchange of Tunneled Hemodialysis Catheters in Chronic Hemodialysis Patients: A Pilot Study

Blood PurifPublished Retrospective study

Authors' conclusion

Our study shows that guidewire exchange of a tunneled HD catheter by creating a new exit site and a new subcutaneous tunnel by using the same venous access is a newer method in chronic HD patients.

Study context

Population
Chronic hemodialysis (HD) patients who needed tunneled catheter exchange because of mechanical dysfunction, June 1, 2015–December 31, 2019
Participants
34 patients49 procedures
Outcome
Feasibility: successful exchange and catheter patency at 6 months
Follow-up
6 months
Methodological detailspilot study
  • Pilot study

Main finding

As reported in the abstract

Procedure success (successful exchange and catheter patency at 6 months)

Success rate of the procedure

43 of 49

87.8%

Catheter insertion failure

0

Catheters with lost patency due to mechanical complication

6

Further findings

Catheter survival censored on death, transplantation, or vascular access creation

Survival at 90 days
97.8%
Survival at 180 days
86.2%
Survival at 1 year
74.5%
Median catheter survival
10.2 months

Safety

Hematomas at insertion site among 49 procedures
9
  • Did not require surgical intervention

Original publication

A New Procedure for Guidewire Exchange of Tunneled Hemodialysis Catheters in Chronic Hemodialysis Patients: A Pilot Study. Blood Purif. Published 6 July 2022. doi:10.1159/000525436

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.