Ultrasonographic Evaluation of Systemic Venous Congestion in Maintenance Hemodialysis Patients during Fluid Removal
Authors' conclusion
Reduction in IVC diameter had a modest but significant correlation with UF volume in our patients on maintenance hemodiafiltration. POCUS may be used to monitor patients during UF.
Study context
- Population
- Patients on maintenance HD (online post-dilutional HDF)32 HDF sessions
- Participants
- 22 patients
- Outcome
- Correlations between changes in POCUS venous congestion parameters and fluid removal
Methodological detailssingle-center
- Single-center
Main finding
As reported in the abstract
Correlation of UF volume with POCUS venous congestion parameters
Mean ultrafiltration (UF) volume
2,084 ± 655 mL
Correlation of UF volume with change in inferior vena cava (IVC) diameter, R
0.34 (0.18, 0.56), p < 0.05 (95% CI)
Key notes
- No correlation of UF volume with any other point-of-care ultrasound (POCUS) venous congestion parameter
Further findings
Baseline congestion · pre-dialysis
- Pre-dialysis weight above bioelectric impedance analysis (BIA) estimated dry weight, average
- 1.9 kg
- Average initial IVC diameter
- <2 cm
- Initial abnormal hepatic vein waveform, % (n) of measurements
- 26% (8)
Normalisation of IVC diameter and hepatic vein (HV) waveform · first UF hour
- Normalisation during the first UF hour in all initially altered measurements
Correlation of IVC diameter reduction with BIA total body water reduction · immediately after fluid removal
- Correlation, R
- 0.34 (0.08, 0.56), p < 0.05 (95% CI)
Original publication
Ultrasonographic Evaluation of Systemic Venous Congestion in Maintenance Hemodialysis Patients during Fluid Removal. Blood Purif. Published 4 November 2024. doi:10. 1159/ 000542012
Composed by AI from the published abstract and checked against it. How Briefs are made →