The effect of using a local skin cooling device on arteriovenous fistula cannulation pain and comfort level of patients on hemodialysis: A single‐blind randomized controlled study
Authors' conclusion
It is concluded that the using lokal skin cooling is an effective tool for reducing pain and enhancing comfort during arteriovenous fistula cannulation in hemodialysis patients.
Study context
- Population
- HD patients undergoing AVF cannulation in the HD units of two state hospitals in Turkey
- Participants
- 50 patients
- Comparison
- Local skin cooling (CoolSense) for five seconds during AVF cannulation vs standard hospital protocol
- Experimentaln = 25
- Controln = 25reference
- Primary endpoint
- AVF cannulation pain (Verbal Category Scale) and comfort level (General Comfort Scale)
Methodological detailssingle-blind, block randomisation, two centres, June 20, 2023 to July 31, 2023
- Single-blind
- Block randomisation
- Two centres
- June 20, 2023 to July 31, 2023
Primary result
As reported in the abstract
AVF cannulation pain and comfort
- Local skin cooling significantly reduced pain and increased comfort, demonstrating an anesthetic effect
- Experimental vs Control: P < 0.001
Further findings
Pain and comfort relationship
- As pain levels decreased, comfort levels increased (p < 0.001)
Original publication
The effect of using a local skin cooling device on arteriovenous fistula cannulation pain and comfort level of patients on hemodialysis: A single‐blind randomized controlled study. Hemodial Int. Published 28 October 2024. doi:10. 1111/ hdi. 13190