The impact of reducing dialysate flows during haemodiafiltration and haemodialysis sessions
Authors' conclusion
Reducing dialysate flows resulted in a major reduction in ultra-pure dialysis water usage and greenhouse gas emissions, with additional reductions in dialysate acid concentrate usage, and electricity without any adverse impact on small or middle molecular weight solute clearances. Extrapolating to a 30-station dialysis unit this would result in an annual reduction of around 9500 kg carbon dioxide equivalent emissions (CO2e) greenhouse gas.
Study context
- Population
- Kidney failure dialysis patients (haemodialysis (HD) and haemodiafiltration (HDF)) in a single UK dialysis centre; 65.8% male, 47.4% diabetic, dialysis vintage 48 (19–108) months
- Participants
- 190 patients
- Comparison
- Reduced dialysate flows vs 500 mL/min
- Outcome
- Dialysate water usage
Methodological detailssingle dialysis centre, evaluated over 3 months
- Single dialysis centre
- Evaluated over 3 months
Main finding
As reported in the abstract
Dialysate water volume per session
- Water reduction, approximately
- 15 554.3 L/week
- Projected annual saving of ultrapure quality water
- 808 821 L
- Projected annual saving accounting for water lost in dialysate production
- 1617 642 L
Key notes
- Mean blood flow 301 ± 16.3 mL/min
Further findings
Sessional KtVurea · pre, 1 month, 3 months
- No difference; pre
- 1.18 ± 0.3
- 1 month
- 1.20 ± 0.37
- 3 months
- 1.16 ± 0.25
Serum β2 microglobulin · pre, 1 month, 3 months
- No difference; pre
- 27.9 ± 6.6 mg/L
- 1 month
- 28.3 ± 7.5 mg/L
- 3 months
- 28.2 ± 6.2 mg/L
Pre-dialysis serum potassium, bicarbonate, phosphate
- No differences
Original publication
The impact of reducing dialysate flows during haemodiafiltration and haemodialysis sessions. J Nephrol. Published 8 June 2026. doi:10. 1093/ joneph/ aajaf076
Composed by AI from the published abstract and checked against it. How Briefs are made →