Tangential biopsy angle and needle depth for adequacy and safety outcomes in ultrasound-guided native kidney biopsy—a single-center experience in a high-risk population
Authors' conclusion
The optimal needle angle for kidney biopsies is 30°-60° for the highest diagnostic yield compared to angles < 30° or > 60°. Our study did not reveal statistically significant differences in major complications between these angle ranges. This greater understanding of the relationship between biopsy angle, needle trajectory depth, and diagnostic and safety outcomes offers valuable insights for optimizing kidney biopsy procedures.
Study context
- Population
- Adults undergoing real-time US-guided percutaneous native kidney biopsy, 2016–2020; excluded pediatric, renal mass or transplant biopsies, incomplete recordsof 443 biopsies
- Participants
- 124 adults
- Exposure
- Biopsy needle cortical tangential angle 30°−60° vs angles < 30° or > 60°; needle depth
- Outcome
- Tissue adequacy
Methodological detailssingle-center
- Single-center
Main finding
As reported in the abstract
| Group | Value | Glomeruli |
|---|---|---|
| 30°−60° | 82.67% | 12 |
| < 30° or > 60° | 59.18% | 5 |
Value
Glomeruli
- 30°−60° vs < 30° or > 60°: P < 0.001 — more glomeruli with 30°−60°
- 30°−60° vs < 30° or > 60°: P = 0.004 — higher with 30°−60°
Key notes
- Needle depth did not significantly impact adequacy
- All technical factors lost statistical significance after adjusting for confounders, except increased echogenicity
Observational data: associations, not effects.
Safety
Major complications · within 24 h
- Major complications
- 12.90%
- Blood transfusions
- 8.06%
- Embolizations
- 3.23%
- No statistically significant differences in major complications between angle ranges
Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →