Adequacy and safety of pediatric native kidney biopsy using 16- and 18-gauge needles
Main finding · Bleeding complicationsResult — go to the resultOdds ratio 2.06 95% CI 1.22–3.47Authors' conclusion
Use of a 16-gauge needle reduces the risk of obtaining an inadequate core in comparison with an 18-gauge. An 18G needle has a safety advantage over a 16G needle in children younger than 12 years. A 16G needle is as safe as an 18G needle and should be used for native kidney biopsy in children older than 12 years.
Study context
- Population
- Children who received a real-time US-guided native kidney biopsy, 2018 to 2024, tertiary pediatric nephrology center644 boys
- Participants
- 1,040 children
- Exposure
- 16-gauge vs 18-gauge needle for native kidney biopsy
- Outcome
- Bleeding complications
Methodological detailssingle-center, tertiary pediatric nephrology center, real-time US-guided, multivariate regression analysis
- Single-center
- Tertiary pediatric nephrology center
- Real-time US-guided
- Multivariate regression analysis
Main finding
Bleeding complications
Odds ratio
2.06
95% CI 1.22–3.47
P = 0.007
16-gaugevs 18-gauge
OR 2.06 (95% CI 1.22–3.47); P = 0.007
As reported in the abstract
- Bleeding complications, overall cohort
- 103 (9.9%)
- Perinephric hematoma
- 86 (8.3%)
- Gross hematuria
- 18 (1.7%)
- Transfusion required
- 3 (0.3%)
Key notes
- Multivariate regression; risk factor in overall cohort and in children under 12 years old
Observational data: associations, not effects.
Further findings
| Outcome | OR (95% CI) | P value | |
|---|---|---|---|
| Inadequate kidney cores | 5.08 (1.07–24.21) | P = 0.041 | |
| 0.050.21520Odds ratio (log scale) |
- Inadequate kidney cores — Inadequate kidney cores, overall
- 37 (4.5%)
Bleeding complications, children aged 12-18 years
- Needle size did not affect complication rates in children aged 12-18 years
Original publication
Adequacy and safety of pediatric native kidney biopsy using 16- and 18-gauge needles. Pediatr Nephrol. Published 22 September 2025. doi:10. 1007/ s00467-025-06973-1