Kidney transplantation

Subclinical rejection-free diagnostic after kidney transplantation using blood gene expression

Kidney IntPublished Diagnostic accuracy study

Authors' conclusion

Thus, our refined SCR score could improve detection of SCR for closer and noninvasive monitoring, allowing early treatment of SCR lesions notably for patients DSA-positive and during lowering of immunosuppressive treatment.

Study context

Population
Kidney transplant recipients with paired blood samples and biopsies at one year after transplantation441 with protocol biopsy
Participants
588 recipients
Outcome
Identification of patients unlikely to develop biopsy-proven subclinical rejection (SCR)
Follow-up
One year after transplantation
Methodological detailsmulticenter, external laboratory validation, independent validation cohort
  • Multicenter
  • External laboratory validation
  • Independent validation cohort

Performance

As reported in the abstract

SCR

C-statistic

0.864

Subclinical rejection (SCR) score

Negative predictive value

98.3%

Further findings

Tolerance score in SCR

Significant decrease of the score of tolerance in 45 patients with biopsy-proven SCR

External validation

SCR score validated in an external laboratory, with quantitative PCR (qPCR) and NanoString, and on 447 patients from an independent multicenter cohort

Reclassification

Score allowed reclassifying patients with discrepancies between donor-specific antibodies (DSA) presence and histological diagnosis of AMR, unlike kidney function

Original publication

Subclinical rejection-free diagnostic after kidney transplantation using blood gene expression. Kidney Int. Published 27 March 2023. doi:10.1016/j.kint.2023.03.019

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.