Blood Gene Expression Profiling and Donor-derived Cell-free DNA to Noninvasively Diagnose Clinical and Subclinical Kidney Transplant Rejection: A Real-life Appraisal Study
Authors' conclusion
In this large, prospective, observational real-life study, we were unable to validate TruGraf and TRAC to diagnose rejection but found a useful context of use for TRAC to noninvasively diagnose AMR/mixed or MVI in conjunction with DSA in dysfunctioning graft.
Study context
- Population
- Unselected, consecutive kidney transplants undergoing for-cause and protocol biopsies with paired blood samples, 6 centers, December 2021 to 2022230 kidney transplants
- Comparison
- TruGraf vs Viracor-TRAC dd-cfDNA for diagnosis of rejection
- Outcome
- Accurate diagnosis of rejection
Methodological detailsprospective, multicentre (6 centers), observational, real-life, blinded central laboratory testing, TruGraf and Viracor-TRAC blindly run by a central laboratory
- Prospective
- Multicentre (6 centers)
- Observational
- Real-life
- Blinded central laboratory testing
- TruGraf and Viracor-TRAC blindly run by a central laboratory
Performance
As reported in the abstract
Diagnosis of any rejection
No biomarker, individually or combined, accurately diagnosed any rejection (AUROC)
< 0.65
Further findings
Incidence of rejection
- Overall
- 22.6%
- Surveillance biopsies
- 17.3%
- For-cause biopsies
- 27%
Biomarker levels and allograft injury
- Inflammation associated with higher TRAC levels; Antibody-mediated rejection (AMR)/mixed and microvascular inflammation (MVI) showed the highest levels
- P < 0.05
- TruGraf did not associate with any specific allograft injury
AMR/mixed rejection or MVI, for-cause biopsies
- High TRAC levels combined with DSA (AUROC)
- 0.817
- P
- P < 0.001
- SCr and DSA (AUROC)
- < 0.65
Original publication
Blood Gene Expression Profiling and Donor-derived Cell-free DNA to Noninvasively Diagnose Clinical and Subclinical Kidney Transplant Rejection: A Real-life Appraisal Study. Transplantation. Published 18 November 2024. doi:10. 1097/ tp. 0000000000005257
Composed by AI from the published abstract and checked against it. How Briefs are made →