Prospective, randomized, multicenter clinical study comparing a self-expanding covered stent to percutaneous transluminal angioplasty for treatment of upper extremity hemodialysis arteriovenous fistula stenosis
Authors' conclusion
Thus, our multicenter, prospective, randomized study of a covered stent used to treat AVF stenosis demonstrated noninferior safety with better TLPP and fewer target-lesion reinterventions than PTA alone through 24 months.
Study context
- Population
- Upper extremity HD patients with arteriovenous fistula (AVF) stenosis of 50% or more and evidence of AVF dysfunction
- Participants
- 142 vs 138
- Comparison
- Covered stent after percutaneous transluminal angioplasty (PTA) vs PTA alone
- Covered stentn = 142
- PTA alonen = 138reference
- Primary endpoint
- 30-day safety (noninferiority) and six-month target lesion primary patency (TLPP) (superiority)
- Follow-up
- 30 days; six months
Methodological detailsprospective, multicenter, noninferiority (30-day safety), superiority (six-month target lesion primary patency (TLPP))
- Prospective
- Multicenter
- Noninferiority (30-day safety)
- Superiority (six-month TLPP)
Primary result
As reported in the abstract
TLPP · six months
Key notes
- Six-month TLPP superior with covered stent vs PTA alone
Further findings
TLPP · 12 months
Mean time between target-lesion reinterventions · 24 months · observed difference; longer with covered stent
| Outcome | Covered stent | PTA alone |
|---|---|---|
| Target-lesion reinterventions · 24 monthsObserved difference; fewer with covered stent | 1.6 ± 1.6 | 2.8 ± 2.0 |
TLPP · 12 months
- 12-month TLPP superior with covered stent vs PTA alone
Access circuit primary patency (ACPP) · six months
- ACPP not statistically different between groups
TLPP · 24 months
- TLPP better with covered stent
- 28.4%
- Observed difference
Safety
30-day safety
- Safety significantly non-inferior with covered stent vs PTA alone
- Noninferiority
Original publication
Prospective, randomized, multicenter clinical study comparing a self-expanding covered stent to percutaneous transluminal angioplasty for treatment of upper extremity hemodialysis arteriovenous fistula stenosis. Kidney Int. Published 27 March 2023. doi:10. 1016/ j. kint. 2023. 03. 015
Composed by AI from the published abstract and checked against it. How Briefs are made →