Point-of-Care Ultrasound in Post-Kidney Transplant Patients: Venous Excess Ultrasound Score and Lung Ultrasound for Fluid Assessment
Authors' conclusion
In this exploratory pilot study, VExUS and LUS provided additional diagnostic information beyond PhE and influenced clinical decision-making in the majority of cases. These hypothesis-generating findings warrant confirmation in larger, multicentre, prospective studies with standardised protocols.
Study context
- Population
- Patients in the immediate post-kidney transplantation period
- Participants
- 31 vs 40
- Exposure
- Combined venous excess ultrasound score (VExUS) + lung ultrasound (LUS) protocol vs standard clinical assessment alone
- Group 1n = 31
- Group 2n = 40reference
- Outcome
- Acute pulmonary oedema
Methodological detailsexploratory, pilot, single-centre, historical reference cohort
- Exploratory
- Pilot
- Single-centre
- Historical reference cohort
Main finding
As reported in the abstract
Fisher exact p = 0.452
Key notes
- Not statistically significant
Observational data: associations, not effects.
Further findings
| Outcome | P value |
|---|---|
| Delayed graft functionGroups differed significantly | P = 0.008 |
| Cold ischaemia timeGroups differed significantly | P = 0.027 |
Correlation of VExUS with bioimpedance analysis (BIA), BNP and Ca125
- VExUS vs BIA, Spearman ρ
- 0.127, p = 0.545
- VExUS vs BNP, ρ
- 0.187, p = 0.349
- VExUS vs Ca125, ρ
- 0.241, p = 0.226
- No correlation
Venous congestion (VExUS grade ≥1) with normal physical examination (PhE) · Day +1
- Detected by VExUS in patients with normal PhE
- 2/14 (14.3%)
Agreement of PhE with ultrasound
- PhE vs VExUS, κ (poor agreement)
- 0.043
- PhE vs LUS, κ (moderate agreement)
- 0.469
Subclinical congestion with normal PhE
- Identified by combined ultrasound
- 28.6%
Therapeutic modifications prompted by ultrasound
- Day +1 (primarily IV fluid reduction)
- 74.2%
- Day +7
- 16.1%
Original publication