Kidney transplantation

Graft Renal Vein Pulsatility as a Marker of Systemic Venous Congestion in Kidney Transplant Recipients: Concordance with the Venous Excess Ultrasound Score (VExUS) Score and Implications for Hemodynamic Management

J NephrolPublished Prospective cohort study

Authors' conclusion

Graft renal vein pulsatility was associated with systemic venous congestion, supporting the transplanted vein as a functional equivalent of the native one. Retrograde pressure transmission into a rigid capsule is a plausible but unproven mechanism. Abnormal pulsatility rules congestion in but, because sensitivity is low, does not rule it out; interventional studies are needed before it guides management.

Study context

Population
Adult kidney transplant recipients80 completed follow-up
Participants
88 recipients
Exposure
Graft renal vein pulsatility vs VExUS-defined systemic venous congestion
Outcome
Association of graft renal vein pulsatility with VExUS-defined congestion
Follow-up
Days 1 and 7, months 1 and 3
Methodological detailsserial assessments on days 1 and 7 and months 1 and 3
  • Serial assessments on days 1 and 7 and months 1 and 3

Main finding

As reported in the abstract

Diagnostic accuracy of graft renal vein pulsatility for VExUS ≥1 · day 1
StrategySensitivitySpecificity
≥30% threshold
42% (20-67)Sensitivity on a scale from 0 to 100 percent
88% (95% CI 78-95)Specificity on a scale from 0 to 100 percent
>50% threshold
26% (9-51)Sensitivity on a scale from 0 to 100 percent
94% (85-98)Specificity on a scale from 0 to 100 percent

Sensitivity

≥30% threshold42% (20-67)
>50% threshold26% (9-51)
Sensitivity on a scale from 0 to 100 percent

Specificity

≥30% threshold88% (95% CI 78-95)
>50% threshold94% (85-98)
Specificity on a scale from 0 to 100 percent
Pulsatility associated with VExUS on days 1 and 7 and month 1, not month 3
all p<0.05

Observational data: associations, not effects.

Further findings

Agreement with VExUS · day 1

Cohen kappa, highest of any method pair
0.32

Discontinuous or reversed flow · day 1

Recipients with discontinuous or reversed flow, too few to estimate
3

Bioimpedance (BIA) and tacrolimus

Pulsatility unrelated to BIA and tacrolimus

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication