Percutaneous peritoneal dialysis catheter making its way to the prevertebral space: A rare occurrence
Authors' conclusion
This case highlights an extremely rare catheter malposition and underscores the importance of early imaging and multidisciplinary management to salvage catheter function.
Study context
- Population
- 33-year-old woman with CKD stage 5 secondary to chronic glomerulonephritis undergoing US-guided percutaneous Tenckhoff catheter insertion for CAPD
- Outcome
- PD catheter malposition
Main finding
As reported in the abstract
- Persistent outflow dysfunction despite adequate inflow
- Imaging: catheter traversed the posterior peritoneal wall into the prevertebral space anterior to L5
- Laparoscopy confirmed; catheter repositioned into the pelvis with closure of the peritoneal defect
- Peritoneal dialysis (PD) subsequently initiated with satisfactory catheter function
Original publication
Percutaneous peritoneal dialysis catheter making its way to the prevertebral space: A rare occurrence. Perit Dial Int. Published 7 September 2026. doi:10. 1177/ 08968608261485134