Novel equations for estimating intraperitoneal pressure among peritoneal dialysis patients
Authors' conclusion
We provided two new equations developed from abdominal anthropometry indices to accurately estimate the IPP in the PD population.
Study context
- Population
- Prevalent peritoneal dialysis (PD) patients
- Participants
- 200 patients
- Exposure
- Estimated intraperitoneal pressure (IPP) vs IPP measured by the Durand method
- Outcome
- Bias, accuracy and precision of eIPP with 2-L and 1.5-L fill volumes vs actual IPP by the Durand method
Methodological detailsdevelopment and validation datasets after random sampling matched by BMI, stepwise linear regression modelling
- Development and validation datasets after random sampling matched by BMI
- Stepwise linear regression modelling
Main finding
As reported in the abstract
Bias, precision and accuracy of eIPP vs Durand method
| Group | Bias (median difference) | Precision (SD of absolute differences) | Estimates differing by >20% |
|---|---|---|---|
| Estimated IPP (eIPP) 2.0 L | −0.24 cmH2O | 2.59 cmH2O | 26% |
| eIPP 1.5 L | −0.10 cmH2O | 2.50 cmH2O | 27% |
Bias (median difference)
Estimated IPP (eIPP) 2.0 L−0.24 cmH2O
eIPP 1.5 L−0.10 cmH2O
Precision (SD of absolute differences)
Estimated IPP (eIPP) 2.0 L2.59 cmH2O
eIPP 1.5 L2.50 cmH2O
Estimates differing by >20%
Estimated IPP (eIPP) 2.0 L26%
eIPP 1.5 L27%
Key notes
- Small biases in relation to the Durand method
Observational data: associations, not effects.
Further findings
- Better bias, precision and accuracy for the eIPP equation than other existing equations for the 2.0-L fill volume
Original publication
Novel equations for estimating intraperitoneal pressure among peritoneal dialysis patients. Clin Kidney J. Published 2 February 2023. doi:10. 1093/ ckj/ sfad021
Composed by AI from the published abstract and checked against it. How Briefs are made →