Peritoneal & home dialysis

Novel Colorimetric and Light Scatter Methods to Identify and Manage Peritoneal Dialysis-Associated Peritonitis at the Point-of-Care

Kidney Int RepPublished Diagnostic accuracy study

Authors' conclusion

These complementary new approaches provide a simple means to obtain information to assist diagnosis at the POC. The first provides antibiotic sensitivity following 10 hours incubation, whereas the second optical approach (QuickCheck), provides instant accurate total leukocyte count.

Study context

Population
Peritoneal dialysis (PD) patient effluent samples and laboratory isolates
Comparison
QuickCheck light-scatter leukocyte count vs spectrophotometry, hemocytometer counting and flow cytometry (Sysmex)
Outcome
Technical performance of the methods
Methodological detailsdevelopment of 2 point-of-care methods, comparison with spectrophotometry, hemocytometer counting and flow cytometry (Sysmex)
  • Development of 2 point-of-care methods
  • Comparison with spectrophotometry, hemocytometer counting and flow cytometry (Sysmex)

Performance

As reported in the abstract

Technical performance of the methods
Test or modelAccuracyCoefficient of variation
QuickCheck94%<4%

QuickCheck

Accuracy94%
Coefficient of variation<4%

Original publication