An initiative to improve effluent culture detection among pediatric patients undergoing peritoneal dialysis through process improvement
Authors' conclusion
An improvement in process time and culture positivity rate occurred following standardization of our PD fluid culture process. Future studies should be aimed at the impact of the components of collection and processing methods on the effluent culture yield.
Study context
- Population
- Pediatric patients undergoing PD with peritonitis
- Comparison
- Post-intervention vs pre-intervention
- Outcome
- Culture detection rate
Methodological detailsPlan-Do-Study-Act cycles, pre-post comparison, sustain phase
- Plan-Do-Study-Act cycles
- Pre-post comparison
- Sustain phase
Main finding
As reported in the abstract
Culture detection rate
Key notes
- National benchmark ≥ 85%
Further findings
Process time
Process reliability · sustain phase
- Individual and moving range chart: decrease in centerline (mean) and upper control limit, process more reliable
Original publication
An initiative to improve effluent culture detection among pediatric patients undergoing peritoneal dialysis through process improvement. Pediatr Nephrol. Published 20 April 2022. doi:10. 1007/ s00467-022-05533-1