Multicenter Validation of a Urine CXCL10 Assay for Noninvasive Monitoring of Renal Transplants
Authors' conclusion
These data demonstrate this urine CXCL10 Luminex immunoassay is robust, reproducible, and accurate, indicating it can be readily translated into clinical HLA laboratories for serial posttransplant surveillance.
Study context
- Population
- Adult kidney transplant recipients in 2 trial cohorts (Basel and TMCT04)468 urines, multicenter cohort
- Comparison
- Luminex vs MSD urine CXCL10 assay
- Outcome
- Luminex assay performance and agreement with MSD
Methodological detailsinternational, 4 laboratories, 2 independent adult kidney transplant trial cohorts (Basel and TMCT04), independent test and validation set, linear mixed-effects model, Four laboratories participated in Luminex assay development and evaluation
- International
- 4 laboratories
- 2 independent adult kidney transplant trial cohorts (Basel and TMCT04)
- Independent test and validation set
- Linear mixed-effects model
- Four laboratories participated in Luminex assay development and evaluation
Performance
As reported in the abstract
- Intra-assay coefficient of variation
- 8.1%
- Interassay coefficient of variation
- 9.3%
- Agreement between 4 laboratories, R
- 0.96 to 0.99, P < 0.001
- Correlation with known CXCL10, single-center cohort (n = 100 urines), R
- 0.94 to 0.98, P < 0.001
- Correlation with known CXCL10, multicenter cohort (n = 468 urines), R
- 0.92, P < 0.001
- Linear mixed-effects model intercept
- −0.490
- Linear mixed-effects model coefficient
- 1.028
Key notes
- Assays not equivalent by Passing-Bablok regression
- Luminex CXCL10 slightly higher than MSD CXCL10, agreement close to 1.0
Further findings
Net reclassification of decision to biopsy after threshold conversion
- Decision to biopsy changed
- 6% (5/85) patients
- Acceptable reclassification
Original publication
Multicenter Validation of a Urine CXCL10 Assay for Noninvasive Monitoring of Renal Transplants. Transplantation. Published 20 June 2023. doi:10. 1097/ tp. 0000000000004554
Composed by AI from the published abstract and checked against it. How Briefs are made →