Hemodialysis

Monitoring strategy of COVID‐19 vaccination in dialysis patients based on a multiplex immunodot method: The CovidDial study

Semin DialPublished Prospective observational study

Authors' conclusion

Three doses of mRNA-1273 vaccine induce a robust but time-limited immunologic response in dialysis patients. Lower anti-spike antibodies titers after initial vaccination are associated with a higher risk to subsequently contract SARS-CoV-2, even beyond 6 months.

Study context

Population
Dialysis patients receiving a 3-dose mRNA-1273 COVID-19 vaccine
Participants
121 patients
Exposure
Subsequently infected vs Not infected
  • Subsequently infectedn = 15
Outcome
Anti-spike antibodies against four epitopes (S1, S2, ECD-S1 + S2, RBD), monitored at baseline and months 1, 3, 6, 9 and 12
Follow-up
Months 1, 3, 6, 9, and 12
Methodological detailsuniform 3-dose schedule, multiplex immunodot enzymatic assay
  • Uniform 3-dose schedule
  • Multiplex immunodot enzymatic assay

Main finding

As reported in the abstract

Anti-spike antibody response

Patients with anti-RBD antibodies at 3 months

96.2%

Patients with anti-RBD antibodies at 12 months

96.8%

Observational data: associations, not effects.

Further findings

OutcomeNot infectedP value
Month-3 mean antibody titers by subsequent SARS-CoV-2 infectionSARS-CoV-2 infected vs Not infected · lower with SARS-CoV-2 infectedmean 85.79 ± 2.61P = 0.0131
anti-RBD85.79 ± 2.61
anti-S1 + S261.68 ± 3.56
anti-S239.70 ± 3.86
Month-3 mean antibody titers by subsequent SARS-CoV-2 infectionSARS-CoV-2 infected vs Not infected · lower with SARS-CoV-2 infectedP = 0.0237
Month-3 mean antibody titers by subsequent SARS-CoV-2 infectionSARS-CoV-2 infected vs Not infected · lower with SARS-CoV-2 infectedP = 0.0096
Response to booster · month 9 and month 12 · Month 12 vs Month 9 · waning 3 months after booster
P < 0.0001
Response to booster · month 9 and month 12 · Month 12 vs Month 9 · waning 3 months after booster
P = 0.0015
  • Month-3 mean antibody titers by subsequent SARS-CoV-2 infection: SARS-CoV-2 infected mean 71.57 ± 9.01 · anti-RBD 71.57 ± 9.01 · anti-S1 + S2 41.07 ± 7.96 · anti-S2 13.79 ± 5.03
  • Month-3 mean antibody titers by subsequent SARS-CoV-2 infection: the group values shown for anti-RBD; all three antibodies in measures

Response to booster · month 9 and month 12

Booster induced a robust serologic response at month 9, with waning 3 months later, particularly for anti-S2 and anti-S1 + S2 antibodies

Original publication

Monitoring strategy of COVID‐19 vaccination in dialysis patients based on a multiplex immunodot method: The CovidDial study. Semin Dial. Published 18 September 2023. doi:10.1111/sdi.13175

Composed by AI from the published abstract and checked against it. How Briefs are made →