Hemodialysis

Leptin Levels and Appetite Score in Patients on Hemodialysis Using High Flux or Medium Cutoff Membranes

J Ren NutrPublished Predefined exploratory analysis of a randomised crossover study

Authors' conclusion

There is no difference between the effects of MCO or high-flux membranes on leptin levels or appetite of CKD patients on hemodialysis.

Study context

Population
Chronic kidney disease (CKD) patients on HD
Participants
32 patients
Comparison
Medium cutoff (MCO) vs high-flux membranes for HD
Primary endpoint
Appetite (Appetite and Food Satisfaction Questionnaire) and leptin levels
Methodological detailsopen, 28 weeks of follow-up
  • Open
  • 28 weeks of follow-up

Primary result

As reported in the abstract

Appetite score, end of treatment period
GroupValueBeginning
Medium cutoffMCO3.00 (range or IQR (not named) 1.00–5.00)3.00 (1.00-5.50)
High-flux2.00 (range or IQR (not named) 0.75–3.25)1.00 (0.25-6.00)

Value

Medium cutoffMCO3.00 (range or IQR (not named) 1.00–5.00)
High-flux2.00 (range or IQR (not named) 0.75–3.25)

Beginning

Medium cutoffMCO3.00 (1.00-5.50)
High-flux1.00 (0.25-6.00)
  • MCO vs High-flux: P = 0.573 — no effect; time P = .376, interaction P = .770

Further findings

Leptin, end of treatment period · interaction P = .218

P = 0.771

Beginning MCO 2,342.30 (1,156.50-4,091.50) · High-flux 2,183.15 (1,550.67-3,656.50)

Leptin, end of treatment period — Time effect: increase in leptin levels in both groups
P = .014

Original publication

Leptin Levels and Appetite Score in Patients on Hemodialysis Using High Flux or Medium Cutoff Membranes. J Ren Nutr. Published 21 July 2023. doi:10.1053/j.jrn.2023.05.007

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.