Plasma Aβ42:Aβ40 ratio as a biomarker for cognitive impairment in haemodialysis patients: a multicentre study
Authors' conclusion
We validated the MoCA-B as an optimal cognitive function screening instrument for MCI in HD patients. The plasma Aβ42:Aβ40 ratio was a potential biomarker in distinguishing normal cognition, MCI and dementia in HD populations.
Study context
- Population
- Patients receiving haemodialysis (HD) in three hospitals in Shanghaimean age 63 y, 55% male
- Participants
- 311 patients
- Exposure
- Normal cognition vs mild cognitive impairment (MCI) vs dementia
- Outcome
- Plasma Aβ42:Aβ40 ratio
Methodological detailsmulticentre
- Multicentre
Main finding
As reported in the abstract
- Plasma Aβ42:Aβ40 ratio significantly reduced in MCI and dementia
- Plasma Aβ42:Aβ40 ratio independently associated with cognitive function after adjusting for age, sex and education levels
- Measured using a single molecule array
Observational data: associations, not effects.
Further findings
Montreal Cognitive Assessment-Basic (MoCA-B) for differentiating MCI and normal cognition
- Best cut-off score
- 24
- AUC
- 0.94
- Validated against neuropsychological batteries in a subset
Serum proteomics
- Neurodegenerative pathways related to Alzheimer's disease (AD) enriched in HD patients with dementia
Original publication
Plasma Aβ42:Aβ40 ratio as a biomarker for cognitive impairment in haemodialysis patients: a multicentre study. Clin Kidney J. Published 19 July 2023. doi:10. 1093/ ckj/ sfad173