Heart & kidney

Intradialytic cardiovascular injury is lowest in high-volume haemodiafiltration: a randomized cross-over trial in four intermittent dialysis strategies

Clin Kidney JPublished Randomised crossover trial

Authors' conclusion

Most EVs increase during HD and HDF. Regarding platelet-derived EVs, HDF appears less biocompatible than HD. Considering CV-related EVs, tissue injury seems less pronounced in HV-HDF. The finding that EV release is IDH-independent needs confirmation.

Study context

Population
Chronic haemodialysis (HD) patients
Participants
40 patients
Comparison
Standard HD (S-HD) vs cool-HD (C-HD) vs low-volume HDF (LV-HDF) vs high-volume haemodiafiltration (HV-HDF)
Primary endpoint
Tissue injury measured by extracellular vesicle (EV) release (blood-cell-derived and cardiovascular (CV)-related EVs, before and after dialysis)
Methodological detailscross-over, BP recorded every 15 minutes
  • Cross-over
  • BP recorded every 15 minutes

Primary result

As reported in the abstract

Rate of change of EVs during dialysis
Platelet-derived extracellular vesicle (EV) increase, LV-HDF
68.4 × 106/ml
Platelet-derived EV increase, HV-HDF
56.1 × 106/ml
Platelet-derived EV increase, S-HD
27.5 × 106/ml
Platelet-derived EVs increased more in LV-HDF and HV-HDF than in S-HD, P for interaction
<.01 respectively .06
Endothelial-derived CD144+ EV increase, HV-HDF
2.3 × 106/ml
Endothelial-derived CD144+ EV increase, S-HD
9.8 × 106/ml
Cardiomyocyte-derived Connexin-43+ EV increase, HV-HDF
12.0 × 106/ml
Cardiomyocyte-derived Connexin-43+ EV increase, S-HD
31.9 × 106/ml
CD144+ and Connexin-43+ EVs increased less in HV-HDF than in S-HD, P for interaction
.03 respectively .06

Further findings

EVs, haemoconcentration-adjusted

Correction for haemoconcentration attenuated all changes; platelet-derived EV increase remained significant in LV-HDF and HV-HDF; CD144+ and Connexin-43+ EVs increased most in S-HD

EV release by intradialytic hypotension (IDH)

EV release similar in patients with varying IDH susceptibility and in sessions with and without IDH

Original publication