Intradialytic cardiovascular injury is lowest in high-volume haemodiafiltration: a randomized cross-over trial in four intermittent dialysis strategies
Authors' conclusion
Most EVs increase during HD and HDF. Regarding platelet-derived EVs, HDF appears less biocompatible than HD. Considering CV-related EVs, tissue injury seems less pronounced in HV-HDF. The finding that EV release is IDH-independent needs confirmation.
Study context
- Population
- Chronic haemodialysis (HD) patients
- Participants
- 40 patients
- Comparison
- Standard HD (S-HD) vs cool-HD (C-HD) vs low-volume HDF (LV-HDF) vs high-volume haemodiafiltration (HV-HDF)
- Primary endpoint
- Tissue injury measured by extracellular vesicle (EV) release (blood-cell-derived and cardiovascular (CV)-related EVs, before and after dialysis)
Methodological detailscross-over, BP recorded every 15 minutes
- Cross-over
- BP recorded every 15 minutes
Primary result
As reported in the abstract
Rate of change of EVs during dialysis
- Platelet-derived extracellular vesicle (EV) increase, LV-HDF
- 68.4 × 106/ml
- Platelet-derived EV increase, HV-HDF
- 56.1 × 106/ml
- Platelet-derived EV increase, S-HD
- 27.5 × 106/ml
- Platelet-derived EVs increased more in LV-HDF and HV-HDF than in S-HD, P for interaction
- <.01 respectively .06
- Endothelial-derived CD144+ EV increase, HV-HDF
- 2.3 × 106/ml
- Endothelial-derived CD144+ EV increase, S-HD
- 9.8 × 106/ml
- Cardiomyocyte-derived Connexin-43+ EV increase, HV-HDF
- 12.0 × 106/ml
- Cardiomyocyte-derived Connexin-43+ EV increase, S-HD
- 31.9 × 106/ml
- CD144+ and Connexin-43+ EVs increased less in HV-HDF than in S-HD, P for interaction
- .03 respectively .06
Key notes
- Leukocyte- and erythrocyte-derived EVs increased in all modalities
- Crude analysis
Further findings
EVs, haemoconcentration-adjusted
- Correction for haemoconcentration attenuated all changes; platelet-derived EV increase remained significant in LV-HDF and HV-HDF; CD144+ and Connexin-43+ EVs increased most in S-HD
EV release by intradialytic hypotension (IDH)
- EV release similar in patients with varying IDH susceptibility and in sessions with and without IDH
Original publication
Intradialytic cardiovascular injury is lowest in high-volume haemodiafiltration: a randomized cross-over trial in four intermittent dialysis strategies. Clin Kidney J. Published 29 April 2024. doi:10. 1093/ ckj/ sfae134
Composed by AI from the published abstract and checked against it. How Briefs are made →