International comparison of home dialysis uptake: a multi-registry analysis from the INTEGRATED Research Group
Authors' conclusion
This study highlights international differences in use of home dialysis within the first year of KRT. Patterns of conversion from facility haemodialysis to home dialysis were also different, underscoring the potential importance of healthcare systems and cultural factors within countries.
Study context
- Population
- Adults over 18 starting dialysis between 1 January 2008 and 31 December 2018
- Participants
- 30,370 / 50,682 / 103,962 / 72,397
- Exposure
- Home dialysis uptake across national registries
- ANZDATAn = 30,370
- CORRn = 50,682
- REINn = 103,962
- UKRRn = 72,397
- Outcome
- Home dialysis initiation within the first year, visualized using cumulative incidences
- Follow-up
- First year
Methodological detailsmulti-registry analysis, clustered Cox regressions
- Multi-registry analysis
- Clustered Cox regressions
Main finding
As reported in the abstract
Home dialysis uptake · 12 months
Key notes
- Range across registries: highest ANZDATA, lowest REIN
Observational data: associations, not effects.
Further findings
Transplant rates · 12 months
- Lowest: New Zealand
- 1.1%
- Highest: UKRR (UK)
- 3.6%
1-year mortality
- Lowest: New Zealand
- 5.5%
- Highest: France and Canada
- 14%
Median age at dialysis initiation
Years
- Lowest: New Zealand
- 59
- Highest: France
- 71
Age and home dialysis
- Increased age was associated with a lower probability of home dialysis
Original publication
International comparison of home dialysis uptake: a multi-registry analysis from the INTEGRATED Research Group. Clin Kidney J. Published 17 August 2026. doi:10. 1093/ ckj/ sfag271
Composed by AI from the published abstract and checked against it. How Briefs are made →