Increased risk of dialysis circuit clotting in hemodialysis patients with COVID‐19 is associated with elevated FVIII, fibrinogen and D‐dimers
Authors' conclusion
Extracorporeal circuit clotting was increased within 4 weeks of testing positive for COVID-19. Clotting was associated with increased factor VIII, fibrinogen and D-dimer, suggesting that the risk of circuit clotting was related to the inflammatory response to COVID-19.
Study context
- Population
- Hemodialysis (HD) patients with COVID-19 detected by PCR, April 2020 to June 202165% male
- Participants
- 203 patients
- Exposure
- HD patients with COVID-19 with vs without extracorporeal circuit clotting
- Extracorporeal circuit clotting (ECC)n = 68
- Outcome
- Extracorporeal circuit clotting
- Follow-up
- 4 weeks before and after COVID-19 PCR detection
Methodological detailsreview of coagulation studies and HD records 4 weeks before and after COVID-19 PCR detection, multivariable logistic analysis
- Review of coagulation studies and HD records 4 weeks before and after COVID-19 PCR detection
- Multivariable logistic analysis
Main finding
As reported in the abstract
ECC
33.5%
68
Key notes
- No clotting recorded prior to positive test results
Observational data: associations, not effects.
Further findings
Factor VIII · greater with ECC
P < 0.001
D-dimers · greater with ECC
P < 0.05
Fibrinogen · greater with ECC
P < 0.05
Circuit clotting, multivariable logistic analysis
| OR (95% CI) | P value | ||
|---|---|---|---|
| Log factor VIII95% confidence limits | 14.8 (1.12–19.6) | P = 0.041 | |
| Fibrinogen95% confidence limits | 1.57 (1.14–21.7) | P = 0.006 | |
| Log D dimer95% confidence limits | 4.8 (1.16–12.5) | P = 0.028 | |
| 0.050.21520Odds ratio (log scale) |
Prothrombin, activated partial thromboplastin and thrombin times
- Not different in those with ECC
Antithrombin, protein C, protein S and platelet counts
- Did not differ
Original publication