Hypothermic Perfusion Modifies the Association Between Anti-LG3 Antibodies and Delayed Graft Function in Kidney Recipients
Authors' conclusion
High anti-LG3 levels are associated with a higher risk of DGF in kidneys exposed to cold storage, but not when hypothermic pump perfusion is used. High anti-LG3 are also associated with a higher risk of graft failure in patients who experience DGF, a clinical manifestation of severe IRI.
Study context
- Population
- Kidney transplant recipients
- Participants
- 687 recipients
- Exposure
- High vs not high pre-transplant anti-LG3 antibodies, by kidney preservation (ice vs hypothermic perfusion pump)
- Outcome
- Delayed graft function (DGF)
Methodological details2 university-affiliated centers
- 2 university-affiliated centers
Main finding
As reported in the abstract
DGF, by preservation method
High anti-LG3 vs Not high anti-LG3Odds ratio (95% CI)
Kidney transported on ice
1.75(1.02–3.00)
Kidney on hypothermic perfusion pump
0.78(0.43–1.37)
Observational data: associations, not effects.
Further findings
Graft failure, by graft function · High anti-LG3 vs Not high anti-LG3
| Outcome | Subdistribution HR (95% CI) | |
|---|---|---|
| Patients with DGF | 4.07 (1.80–9.22) | |
| Patients with immediate graft function | 0.50 (0.19–1.29) | |
| 0.10.31310Subdistribution hazard ratio (log scale) |
Original publication
Hypothermic Perfusion Modifies the Association Between Anti-LG3 Antibodies and Delayed Graft Function in Kidney Recipients. Transpl Int. Published 20 February 2023. doi:10. 3389/ ti. 2023. 10749
Composed by AI from the published abstract and checked against it. How Briefs are made →