Machine perfusion modulates cold-preservation injury in kidney transplantation: IDEAL stage 4 United States population cohort study
Authors' conclusion
In conclusion, HMP reduces the negative impact of each additional hour of CPT. Therefore, the treatment effect is not fixed and increases as CPT increases, likely explaining the lack of benefit in trials of short-duration eiHMP.
Study context
- Population
- Single-kidney-transplant recipients in the US (OPTN, 2010–2024)
- Participants
- 137,835 recipients
- Exposure
- Hypothermic machine perfusion (HMP) vs static cold storage
- Outcome
- Delayed graft function
Methodological detailsIDEAL stage 4, OPTN registry data 2010-2024, multivariable nonlinear (restricted cubic spline) regression with interaction terms
- IDEAL stage 4
- OPTN registry data 2010-2024
- Multivariable nonlinear (restricted cubic spline) regression with interaction terms
Main finding
As reported in the abstract
Delayed graft function
Each group vs SCSAdjusted odds ratio (95% CI)
cHMP
0.484(0.467–0.501)
eiHMP
0.459(0.435–0.485)
transport-only-HMP
0.535(0.512–0.558)
Observational data: associations, not effects.
Further findings
Cold-preservation time (CPT)
- End-ischemic-HMP (eiHMP)
- median 23.0 (IQR 17.3–30.5) hours
- Median CPT overall (IQR 12.0-22.9)
- 17.3 hours
Interaction of HMP with CPT
- HMP mitigated the negative effect of increasing CPT vs static cold storage (SCS)
- Continuous HMP (cHMP) showed benefit across all CPTs; eiHMP beneficial only at longer CPTs
LOS
- HMP associated with significant reductions in LOS
Graft and patient survival · 5-year
- HMP associated with improved 5-year graft and patient survival
Original publication
Machine perfusion modulates cold-preservation injury in kidney transplantation: IDEAL stage 4 United States population cohort study. Am J Transplant. Published 24 February 2026. doi:10. 1016/ j. ajt. 2026. 02. 025
Composed by AI from the published abstract and checked against it. How Briefs are made →